Configuration
77
Type
Explanation
Can be assigned
to partitions
HUA Confirm Timer
This output is activated while the timer for confirmation of
a hold up alarm is running and is deactivated as soon as
the timer has expired.
No
Duress Code
A duress code has been used. The alarm panel activates
the output as soon as a user enters a duress code and
deactivates the output again when the user resets the
system.
Yes
Confirmed Alarm
This output is activated when an alarm is interrupted by
the user in the selected partition during the possible time
period. The output is deactivated again when the alarm is
confirmed.
Yes
Fire
This output is activated when a fire alarm is triggered.
yes
Technical Alarm
This output is activated when a zone with the attribute
"Technical Alarm" triggers an alarm. It is only deactivated
again when the zone triggering the alarm is reset (cause
for the technical alarm has been corrected) AND the user
confirms the technical alarm on the alarm panel with a
valid code.
Yes
24 hours)
This output is activated when a zone with the attribute "24
Hour Alarm" triggers an alarm.
Yes
Zone Alarm
This output is activated when the selected zone reports
an alarm and is deactivated again when the alarm is re-
set.
No
External Siren
This output is activated when there is a local alarm in the
selected partition for the set siren time of the external si-
ren.
The output does not activate for a technical alarm or hold
up alarm.
Yes
Internal Siren
This output is activated when there is a local alarm in the
selected partition for the set siren time of the internal si-
ren.
The output does not activate for a technical alarm or hold
up alarm.
Yes
External Strobe
This output is activated when there is a local alarm in the
selected partition and remains activated until the wireless
alarm panel is disarmed.
The output is also activated for 10 seconds after the parti-
tion has been successfully armed if the
EXTERNAL
strobe signal for confirmation has been activated.
Yes
Internal Strobe
This output is activated when there is a local alarm in the
selected partition and remains activated until the wireless
alarm panel is disarmed.
The output is also activated for 10 seconds after the parti-
tion has been successfully armed if the
INTERNAL
strobe
signal for confirmation has been activated.
Yes
Alarm Abort
The output is activated when an alarm is interrupted by
the user in the selected partition during the possible time
period. The output is deactivated as soon as the alarm is
confirmed.
Yes
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......