Appendix
282
Lpref
Account prefix
5.5.1.6.2
No
L0 is sent
#acct
Account num-
ber
5.5.1.6.1
Yes
Pad
5.5.1.7
Yes
Within the parentheses "[" and "]"
Data
5.5.1.7
Yes
Within the parentheses "[" and "]"
Timestamp
5.5.1.9
Yes
Only in encrypted messages.
Is GMT
Time difference (inaccuracy) between central time
and ARC/ESCC recipient time must be max. +20/-40
seconds.
CR
5.5.1.10
Yes
CID/SIA Events
This menu only appears if you select "Contact ID" or one of the SIA versions at the following point:
Installer Mode -> Communication -> ARC Reporting -> Protocol
A detailed description of the CID and SIA formats can be found in the "ARC (ESCC) reporting protocol formats" ap-
pendix
To simplify the programming, the possible CID/SIA events are assigned to corresponding groups. In Table 1 and 3,
you can see the CID/SIA events with the corresponding group assignment. In Table 2 and 4, you can see the groups
with the corresponding CID/SIA events.
If you approve a group using "Yes", the alarm control panel can send every event from this group.
Notes:
CID/SIA alarm transmissions require significantly more time than Scancom Fast Format as the system transfers ex-
tended alarm data to the alarm receiving centre (ARC, ESCC).
Note
The alarm control panel delays the ARC reporting and entering in the log book by approx. 15-22 minutes (randomly),
either in the event of a mains failure (power cut) or when leaving the Installer Mode with an existing mains failure
(power cut).
The alarm control panel delays the ARC reporting and entering in the log book by approx. 60-90 seconds (randomly),
either once the power supply is restored or when leaving the Installer Mode and the power supply is restored.
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......