Configuration
134
Name/function
Explanation (checkbox)
RF Jamming
Dropdown selection field for alarm system response for jamming:
The alarm panel can detect jamming of wireless signals.
Corresponding processes are activated as follows:
Alarm panel is armed
Alarm panel is disarmed
Disabled
No response
No response
Fault
Log book entry of this
event
No
display and no warning
tones
Log book entry of this event
Display and warning tones
Tamper Ac-
tivated
Tampering alarm
Jamming is reported
Note
:
If "Tamp as Tamp-Only" is disa-
bled, the "Jamming" or "Fault"
outputs are also activated.
If no tamper channel is assigned
in FF, an "unconfirmed alarm" is
sent.
Tampering alarm
Jamming is reported
Note
If "Tamp as Tamp-Only" is disa-
bled, the "Jamming" or "Fault"
outputs are also activated.
If no tamper channel is assigned
in FF, an "unconfirmed alarm" is
sent.
Note
The "Tamper" option is required in order to comply with PD 6662:2010.
If the "Tamper" option is used along with the following setting:
System -> User Reset -> System Tampers = No
the user cannot reset the system.
Remote Updates
Alarm panel
Installer Mode -> System -> Security -> Remote Updates -> Blocked*/Enabled
WBI
Installer Mode -> System -> Security Settings -> Remote Updates -> Blocked (deac-
tivated, not ticked)*/Enabled (activated, ticked)
Blocked (deactivated
– not ticked)*
Enabled (activated
– ticked)
If this option is activated, a new Level 4 code must be entered. This is only
the case if this Level 4 code was never programmed to begin with (as deliv-
ered or since the last reset to the factory defaults). This Level 4 code has
the same number of digits as the Installer code or the User code.
Enter a "New Level 4 code" and "Confirm Level 4 code" (enter the code
again to confirm it).
A new user is added automatically. See "User" menu.
Name: "Level4"
Note:
For security reasons, you should change the "Level4" default name of
the Level 4 user.
The user themselves or the administrator can change the name of this user.
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......