Configuration
102
Name/function
Explanation
Siren Delay [min] (ARC)
Time for the delay duration of the siren(s).
The siren delay can be set to a value between 0 and 10 min.
When an alarm has been triggered the alarm panel waits until this time has expired
before it activates the sirens.
Note
The siren delay only goes into effect when the alarm response includes comms.
The siren delay does not go into effect when a comms fault occurs.
The siren delay will not be active when "Installer Mode->System->Confirmation-
>Confirmation Mode->DD243 or BS8243" and "Installer Mode->System->Confirma-
tion->Siren On ->Unconfirm" are set.
If sounders (or just control devices?) are assigned to multiple partitions, the alarm
panel uses the shortest siren delay set for the partitions in question.
Note
Detailed information on the siren delay can be found under Siren Delay Partitions
All Set.
Note
If under System -
> Security, “Siren Delay (user-based)” is enabled (> 0), this menu
item does
not
appear here.
And the entire behaviour of the siren delay (ARC) is blocked!
Ext. Siren Time [min]
Time for the duration of the external siren(s) in minutes.
The siren time can be set to a value between 0 and 15 min.
If sounders (or just control devices?) are assigned to multiple partitions, the alarm
panel uses the longest siren time set for the partitions in question.
The time for which the sounders are active can also be extended to the longest si-
ren delay for that partition.
Pt.Set Final Exit
This option controls how a "Final Door" zone is handled when the system is inter-
nally armed.
Final Door
Every zone in this partition with type "Final Door" and the attribute
"Part Set" continues to function as a "Final Door" zone.
Normal Alarm
Every zone in this partition with type "Final Door" and the attribute
"Part Set" functions as a "Normal Alarm" zone.
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...