Note
Action
Cable harness can stay connected to all
connectors except to the SMB unit.
Remove the
bracket
by sliding it off the re-
maining three attachment screws and put
it at a 90° angle from the base.
6
xx0900000013
Putting the bracket at a 90° angle facilitates
the disconnecting of cables from the
bracket.
Note
Use caution when performing this procedure
order not to damage cables or other com-
ponents!
Parts:
A Bracket at a 90° angle
B Base
A
xx0900000035
Disconnect cable clamps.
7
Parts:
A Cable clamps
See the figure in:
•
Location of SMB unit on page 239
Unscrew the
attachment screws
securing
the SMB unit just enough to be able to re-
move the SMB unit.
8
Remove the SMB unit.
9
xx1700000993
Disconnect the battery cable by pressing
down the upper lip of the R1.G connector
to release the lock while pulling the connect-
or upwards.
10
See the figure in:
•
Location of SMB unit on page 239
Disconnect the remaining connectors on
the SMB unit:
•
R1.SMB1-2
•
R1.SMB3-6
•
R2.SMB
11
Continues on next page
242
Product manual - IRB 2600
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
4 Repair
4.3.4 Replacing SMB unit
Continued
Содержание IRB 2600ID
Страница 1: ...ROBOTICS Product manual IRB 2600 ...
Страница 2: ...Trace back information Workspace 23B version a11 Checked in 2023 06 20 Skribenta version 5 5 019 ...
Страница 8: ...This page is intentionally left blank ...
Страница 114: ...This page is intentionally left blank ...
Страница 444: ...This page is intentionally left blank ...
Страница 456: ...This page is intentionally left blank ...
Страница 458: ...This page is intentionally left blank ...
Страница 464: ......
Страница 465: ......