Note
Action
xx0800000336
Move the robot to the position shown in the
figure.
3
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
4
xx0800000335
Remove the
bracket
securing the cable
package to the tubular shaft unit by remov-
ing its attachment screws.
5
Parts:
•
A: Tubular shaft unit
•
B: Attachment screws M6x16 qual-
ity 8.8-A2F (2 pcs)
•
C: Bracket
Place the cable package in a way that it will
not be damaged in the continued removal
procedure.
6
How to remove motors is described in
section:
•
Remove motors axes 4, 5 and 6.
7
How to remove the wrist unit is detailed
in section:
•
Removal of wrist unit on page 269
Tip
If only the tubular shaft unit shall be re-
placed, it is a good idea to remove the
wrist
unit
at this stage.
8
Continues on next page
262
Product manual - IRB 2600
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
4 Repair
4.4.2 Replacing complete tubular shaft unit
Continued