Note
Action
xx0900000100
Remove the screw that secures the bracket
and unscrew the three other screws a little
just enough to be able to slide the bracket
sideways.
10
Parts:
•
A: Screw to be removed
•
B: Screws to be unscrewed (3 pcs)
xx0900000013
Remove the
bracket
by sliding it off the re-
maining three attachment screws and put
it at a 90° angle from the base.
Putting the bracket at a 90° angle facilitates
the disconnecting of cables from the
bracket.
Note
Use caution when performing this procedure
in order not to damage cables or other
components!
11
Parts:
•
A: Bracket at a 90° angle
•
B: Base
A
B
C
D
xx1200000890
A R1.CP/CS
B R1.MP
C Air hose connector
D R1.SMB
Remove connectors and air hose connector
completely from the
bracket
:
•
R1.CP/CS
•
R1.MP
•
R1.SMB
•
Air hose connector
•
R1.ETHERNET (if used)
12
How to remove the
SMB unit
is described
in section:
•
Removing the SMB unit on page 240
Remove the
SMB unit
from its attachment
screws.
Leave the screws in the base.
13
Continues on next page
206
Product manual - IRB 2600
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
4 Repair
4.3.1 Removing the complete cable harness
Continued
Содержание IRB 2600ID
Страница 1: ...ROBOTICS Product manual IRB 2600 ...
Страница 2: ...Trace back information Workspace 23B version a11 Checked in 2023 06 20 Skribenta version 5 5 019 ...
Страница 8: ...This page is intentionally left blank ...
Страница 114: ...This page is intentionally left blank ...
Страница 444: ...This page is intentionally left blank ...
Страница 456: ...This page is intentionally left blank ...
Страница 458: ...This page is intentionally left blank ...
Страница 464: ......
Страница 465: ......