Calibration method
Description
Type of calibration
Wrist Optimization
Optimization of TCP reorientation perform-
ance. The purpose is to improve reorientation
accuracy for continuous processes like weld-
ing and gluing.
Optimization
Wrist optimization will update standard calib-
ration data for axes 4, 5 and 6.
i
The robot is calibrated by either Calibration Pendulum or Axis Calibration at factory. Always use
the same calibration method as used at the factory.
Information about valid calibration method is found on the calibration label or in the calibration
menu on the FlexPendant.
If no data is found related to standard calibration, contact the local ABB Service.
Brief description of calibration methods
Calibration Pendulum method
Calibration Pendulum is a standard calibration method for calibration of many of
ABB robots (except IRB 6400R, IRB 640, IRB 1400H, and IRB 4400S). This
calibration method is not used on OmniCore robots.
Two different routines are available for the Calibration Pendulum method:
•
Calibration Pendulum II
•
Reference calibration
The calibration equipment for Calibration Pendulum is delivered as a complete
toolkit, including the
Operating manual - Calibration Pendulum
, which describes
the method and the different routines further.
Axis Calibration method
Axis Calibration is a standard calibration method for calibration of IRB 2600/IRB
2600 ID. It is the recommended method in order to achieve proper performance.
The following routines are available for the Axis Calibration method:
•
Fine calibration
•
Update revolution counters
•
Reference calibration
The calibration equipment for Axis Calibration is delivered as a toolkit.
An introduction to the calibration method is given in this manual, see
with Axis Calibration method on page 412
The actual instructions of how to perform the calibration procedure and what to
do at each step is given on the FlexPendant. You will be guided through the
calibration procedure, step by step.
Wrist Optimization method
Wrist Optimization is a method for improving reorientation accuracy for continuous
processes like welding and gluing and is a complement to the standard calibration
method.
The actual instructions of how to perform the wrist optimization procedure is given
on the FlexPendant.
Continues on next page
Product manual - IRB 2600
399
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
5 Calibration
5.1.2 Calibration methods
Continued
Содержание IRB 2600ID
Страница 1: ...ROBOTICS Product manual IRB 2600 ...
Страница 2: ...Trace back information Workspace 23B version a11 Checked in 2023 06 20 Skribenta version 5 5 019 ...
Страница 8: ...This page is intentionally left blank ...
Страница 114: ...This page is intentionally left blank ...
Страница 444: ...This page is intentionally left blank ...
Страница 456: ...This page is intentionally left blank ...
Страница 458: ...This page is intentionally left blank ...
Страница 464: ......
Страница 465: ......