Information
Action
A
B
xx1000000937
Remove
motor axis 5
by unscrewing its at-
tachment screws.
21
Parts:
•
A: Upper arm tube
•
B: Motor axis 5
Refitting motor axis 5
Use this procedure to refit motor axis 5.
Information
Action
Place motor axis 5 in the upper arm tube.
1
A
B
xx1000000937
Tighten the attachment screws just enough
to still be able to move the motor.
2
Parts:
•
A: Upper arm tube
•
B: Motor axis 5
Adjust the play by finding the smallest play.
3
Tightening torque: 10 Nm.
Secure the motor with its attachment
screws.
4
Lift the upper arm tube to the robot.
5
Continues on next page
342
Product manual - IRB 2600
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
4 Repair
4.7.3 Replacing motor axis 5 - IRB 2600ID
Continued