Note
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before handling
the unit read the safety information in section
The unit is sensitive to ESD on page 56
2
Maximum tightening torque: 5 Nm.
Secure the brake release board to the
bracket
with its
nuts with flange
.
3
See the figure in:
•
Location of brake release board
on page 245
X9
X8
X10
xx1700000978
Reconnect
connectors X8
,
X9
and
X10
to the
brake release board.
Be careful not to damage the sockets or pins.
Make sure the connector and its locking arms
are snapped down properly.
4
Verify that the robot cabling is positioned
correctly, according to previously taken pic-
ture/notes.
WARNING
Screened cables must not get in contact with
the brake release board after installation.
Eliminate all risks of contact between
screened cables and the brake release board.
5
A
B
C
xx0800000456
Use caution when pushing the
base cover
into position while at the same time checking
that no cables are damaged.
6
Parts:
A Base
B Base cover
C Attachment screws M6x16 quality
8.8-A2F (6 pcs)
Secure the
base cover
with its
attachment
screws
.
7
Continues on next page
248
Product manual - IRB 2600
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
4 Repair
4.3.5 Replacing the brake release board
Continued
Содержание IRB 2600ID
Страница 1: ...ROBOTICS Product manual IRB 2600 ...
Страница 2: ...Trace back information Workspace 23B version a11 Checked in 2023 06 20 Skribenta version 5 5 019 ...
Страница 8: ...This page is intentionally left blank ...
Страница 114: ...This page is intentionally left blank ...
Страница 444: ...This page is intentionally left blank ...
Страница 456: ...This page is intentionally left blank ...
Страница 458: ...This page is intentionally left blank ...
Страница 464: ......
Страница 465: ......