Removal of wrist unit
Use this procedure to remove the wrist unit.
Note
Action
Decide which calibration routine to use, and
take actions accordingly prior to beginning the
repair procedure.
1
xx0800000329
Move the upper arm to a position where the
wrist is pointing towards the floor as shown in
the figure.
This way the wrist can be removed without
drainage.
2
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
3
WARNING
Handling gearbox oil involves several safety
risks, see
Gearbox lubricants (oil or grease) on
4
CAUTION
The robot wrist unit weighs 15 kg.
All lifting accessories used must be sized ac-
cordingly!
5
See the figure in:
•
Location of wrist unit on
page 267
Remove the
attachment screws
and carefully
remove the wrist unit.
CAUTION
Do not damage the gears.
6
WARNING
The wrist unit is filled with oil. Perform removal
with care.
Continues on next page
Product manual - IRB 2600
269
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
4 Repair
4.4.3 Replacing wrist unit
Continued
Содержание IRB 2600ID
Страница 1: ...ROBOTICS Product manual IRB 2600 ...
Страница 2: ...Trace back information Workspace 23B version a11 Checked in 2023 06 20 Skribenta version 5 5 019 ...
Страница 8: ...This page is intentionally left blank ...
Страница 114: ...This page is intentionally left blank ...
Страница 444: ...This page is intentionally left blank ...
Страница 456: ...This page is intentionally left blank ...
Страница 458: ...This page is intentionally left blank ...
Страница 464: ......
Страница 465: ......