Information
Action
xx1000000931
Fit the
cable protection
with its
nuts
.
4
Parts:
A Cable protection
B Nuts (2 pcs)
C Connector motor axis 6
Refitting the wrist
Information
Action
Clean all assembly surfaces.
1
Remove any painting from the assembly
surfaces, with a knife.
Place the wrist with the axis-6 motor fitted
a little into the upper arm tube.
2
R4.MP6
R4.FB6
xx1400002575
Reconnect the cables R4.MP6 and R4.FB6
to the axis-6 motor.
3
xx1000000932
Remove the
short screws
temporarily used
to secure from leakage from the wrist.
4
Parts:
A Short screws (2 pcs)
Continues on next page
Product manual - IRB 2600
355
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
4 Repair
4.7.4 Replacing motor axis 6 and wrist unit - IRB 2600ID
Continued