93
Actual signals and parameters
DI1
DI2
Operation
1
1
No constant speed
0
1
Speed defined by parameter
1202
CONST SPEED 1
1
0
Speed defined by parameter
1203
CONST SPEED 2
0
0
Speed defined by parameter
1204
CONST SPEED 3
Parameters in the Long parameter mode
Index
Name/Selection
Description
Def
-5 = DI5(INV)
Speed defined by parameter
1202
CONST SPEED 1 is activated through
inverted digital input DI5. 0 = active, 1 = inactive.
-7 = DI1,2 (INV)
Constant speed selection through inverted digital inputs DI1 and DI2.
1 = DI active, 0 = DI inactive.
-8 = DI2,3 (INV)
See selection DI1,2 (INV).
-9 = DI3,4 (INV)
See selection DI1,2 (INV).
-10 = DI4,5 (INV)
See selection DI1,2 (INV).
-12 = DI1,2,3 (INV)
Constant speed selection through inverted digital inputs DI1, DI2 and DI3.
1 = DI active, 0 = DI inactive.
DI1
DI2
DI3
Operation
1
1
1
No constant speed
0
1
1
Speed defined by parameter
1202
CONST SPEED 1
1
0
1
Speed defined by parameter
1203
CONST SPEED 2
0
0
1
Speed defined by parameter
1204
CONST SPEED 3
1
1
0
Speed defined by parameter
1205
CONST SPEED 4
0
1
0
Speed defined by parameter
1206
CONST SPEED 5
1
0
0
Speed defined by parameter
1207
CONST SPEED 6
0
0
0
Speed defined by parameter
1208
CONST SPEED 7
-13 = DI3,4,5 (INV)
See selection DI1,2,3(INV).
1202
CONST SPEED 1
Defines constant speed 1 (that is drive output frequency).
E: 5.0 Hz /
U: 6.0 Hz
0.0
…500.0 Hz
Output frequency
1203
CONST SPEED 2
Defines constant speed 2 (that is drive output frequency).
E: 10.0 Hz /
U: 12.0 Hz
0.0
…500.0 Hz
Output frequency
1204
CONST SPEED 3
Defines constant speed 3 (that is drive output frequency).
E: 15.0 Hz /
U: 18.0 Hz
0.0
…500.0 Hz
Output frequency
1205
CONST SPEED 4
Defines constant speed 4 (that is drive output frequency).
E: 20.0 Hz /
U: 24.0 Hz
0.0
…500.0 Hz
Output frequency
1206
CONST SPEED 5
Defines constant speed 5 (that is drive output frequency).
E: 25.0 Hz /
U: 30.0 Hz
0.0
…500.0 Hz
Output frequency
1207
CONST SPEED 6
Defines constant speed 6 (that is drive output frequency).
E: 40.0 Hz /
U: 48.0 Hz
0.0
…500.0 Hz
Output frequency
1208
CONST SPEED 7
Defines constant speed 7 (that is drive output frequency). Note that constant
speed 7 may be used also as jogging speed (
1010
JOGGING SEL) and with
fault function
3001
AI<MIN FUNCTION.
E: 50.0 Hz /
U: 60.0 Hz
0.0
…500.0 Hz
Output frequency
Содержание ACS150 series
Страница 4: ......
Страница 5: ......
Страница 15: ...14 Safety ...
Страница 19: ...18 Introduction to the manual ...
Страница 39: ...38 Planning the electrical installation ...
Страница 51: ...50 Installation checklist ...
Страница 57: ...56 Start up and control with I O ...
Страница 69: ...68 Control panel ...
Страница 79: ...78 Application macros ...
Страница 160: ...L Q M 0 I II D I II I I ro I m D en m D D Q Q f 3AFE68633931 A 0 Frame size R2 IP20 INEMA 1 ...
Страница 161: ...ji 4 I 5 I 6 4 J ...
Страница 162: ......
Страница 163: ...160 Dimension drawings ...
Страница 169: ...166 Appendix Process PID control ...
Страница 171: ...168 ...