66
Control panel
12
.
0
Hz
PAR
SET
FWD
Step
Action
Display
6.
changed the parameter value,
SET
starts flashing.
• To save the displayed parameter value, press
.
• To cancel the new value and keep the original, press
.
LOC
LOC
1203
PAR
FWD
103
PAR
SET
FWD
104
PAR
SET
FWD
LOC
105
PAR
SET
FWD
0
.
0
Hz
PAR
SET
FWD
500
.
0
Hz
LOC
PAR
SET
FWD
Step
Action
Display
1.
they are displayed with group
34 PANEL DISPLAY
parameters. See page
65
for detailed instructions on changing parameter values.
0105
TORQUE.
To change the default signals, select from group
01 OPERATING DATA
up
to three signals to be browsed.
Signal 1: Change the value of parameter
3401
SIGNAL1 PARAM to the
index of the signal parameter in group
01 OPERATING DATA
(= number of
the parameter without the leading zero), for example, 105 means
parameter
0105
TORQUE. Value 0 means that no signal is displayed.
Repeat for signals 2 (
3408
SIGNAL2 PARAM) and 3 (
3415
SIGNAL3
PARAM). For example, if
3401
SIGNAL1 PARAM = 0 and
3415
SIGNAL3
PARAM = 0, browsing is disabled and only the signal specified by
3408
SIGNAL2 PARAM appears on the display. If all three parameters are set to
0, that is no signals are selected for monitoring, the panel displays text
“n.A.”.
LOC
LOC
2.
Specify the decimal point location, or use the decimal point location and
unit of the source signal (setting 9 [DIRECT]). For details, see parameter
3404
OUTPUT1 DSP FORM.
Signal 1: parameter
3404
OUTPUT1 DSP FORM
Signal 2: parameter
3411
OUTPUT2 DSP FORM
Signal 3: parameter
3418
OUTPUT3 DSP FORM.
LOC
9
PAR
SET
FWD
3.
Select the units to be displayed for the signals. This has no effect if
parameter
3404
/
3411
/
3418
is set to 9 (DIRECT). For details, see
parameter
3405
OUTPUT1 UNIT.
Signal 1: parameter
3405
OUTPUT1 UNIT
Signal 2: parameter
3412
OUTPUT2 UNIT
Signal 3: parameter
3419
OUTPUT3 UNIT.
LOC
3
PAR
SET
FWD
4.
maximum display values. This has no effect if parameter
3404
/
3411
/
3418
is
set to 9 (DIRECT). For details, see parameters
3406
OUTPUT1 MIN and
3407
OUTPUT1 MAX.
Signal 1: parameters
3406
OUTPUT1 MIN and
3407
OUTPUT1 MAX
Signal 2: parameters
3413
OUTPUT2 MIN and
3414
OUTPUT2 MAX
Signal 3: parameters
3420
OUTPUT3 MIN and
3421
OUTPUT3 MAX.
LOC
Use keys
and
to select the parameter value. When you have
How to select the monitored signals
You can select which signals are monitored in the Output mode and how
By default, the display shows:
0103
OUTPUT FREQ,
0104
CURRENT and
Select the scalings for the signals by specifying the minimum and
Содержание ACS150 series
Страница 4: ......
Страница 5: ......
Страница 15: ...14 Safety ...
Страница 19: ...18 Introduction to the manual ...
Страница 39: ...38 Planning the electrical installation ...
Страница 51: ...50 Installation checklist ...
Страница 57: ...56 Start up and control with I O ...
Страница 69: ...68 Control panel ...
Страница 79: ...78 Application macros ...
Страница 160: ...L Q M 0 I II D I II I I ro I m D en m D D Q Q f 3AFE68633931 A 0 Frame size R2 IP20 INEMA 1 ...
Страница 161: ...ji 4 I 5 I 6 4 J ...
Страница 162: ......
Страница 163: ...160 Dimension drawings ...
Страница 169: ...166 Appendix Process PID control ...
Страница 171: ...168 ...