INSTRUMENT DESCRIPTION
Laser TIRF 3
Technical Data
Carl Zeiss
02/2014
423683-7144-001
47
2.14
Technical Data
Dimensions (width x depth x height)
Axio Observer stand ....................................................................... approx. 295 mm x 805 mm x 707 mm
Slider Laser TIRF ............................................................................................. 280 mm x 90 mm x 80 mm
Signal distribution box ................................................................................. 250 mm x 95 mm x 220 mm
TIRF controller ............................................................................................. 250 mm x 95 mm x 220 mm
Laser safety cover ............................................................................ approx. 200 mm x 150 mm x 15 mm
Incubator XLmulti S1 RED / DARK LS ......................................................... 610 mm x 415 mm x 410 mm
Signal distribution box ..................................................................................... 30 mm x 55 mm x 85 mm
Laser Bench Tower ..................................................................................... 310 mm x 448 mm x 465 mm
Laser Bench Rack/ Laser Bench Rack 3F ....................................................... 600 mm x 706 mm x 558 mm
Coupling module (Laser Bench Tower) ........................................................ 177 mm x 448 mm x 462 mm
Weight
Axio Observer.Z1 (without external power supply unit)........................................................ approx. 15 kg
Slider Laser TIRF ................................................................................................................. approx. 570 g
Signal distribution box ......................................................................................................... approx. 2 kg
TIRF Controller ..................................................................................................................... approx. 2 kg
Laser safety cover .............................................................................................................. approx. 465 g
Laser Bench Tower ....................................................................................................................... 25.5 kg
Laser Bench Rack ......................................................................................................................... 52.5 kg
Laser Bench Rack 3F ....................................................................................................................... 55 kg
Ambient Conditions
Transportation (in packaging)
Admissible ambient temperature .................................................................................... -20 °C to +55 °C
Admissible relative humidity (no condensation) .......................................................... max. 75 % at 35 °C
Storage
Admissible ambient temperature ..................................................................................... +5 °C to +40 °C
Admissible relative humidity (no condensation) .......................................................... max. 75 % at 35 °C
Operation
Admissible ambient temperature ......................................................... +15 °C to +35 °C, optimum 22 °C
Admissible relative humidity ..................................................................................... max. 65 % at 30 °C
Atmospheric pressure ..............................................................................................800 hPa to 1060 hPa
Operation altitude ............................................................................................................. max. 2000 m
Pollution degree ................................................................................................................................... 2