15.12
External axes overrun
WARNING!
Danger of injury and damage to property if the signal is not working
The settings must be performed to activate the external axis overrun. If not, this function will
not be activated even if the signal is input, thus personal injury and/or equipment damage
may result.
Before use, make sure to perform the settings of the external axis overrun. After that,
confirm that the overrun alarm occurs by turning OFF the external axis overrun signal.
In units with standard specifications without an external axis, the input signal for
overrunning of an external axis is not used. In this case, a jumper cable is installed (refer to
the following figure).
If an input signal overspeed is necessary for an external axis, connect the signal input
circuits as described below.
For safety reasons, redundant = two-channel switches have to be used for the overrun
signal input for external axes. Connect the signal input of the external axis this way that both
input signals are turned ON or OFF at the same time.
If only one signal is turned ON, the machine safety signal error occurs. For the setting of
the external axis overrun, refer to chapter "Addition of base and Station axes" to the manual
Instructions with the document-no.: E1102000214XX01* and higher.
The figure below shows the factory standard wiring, where all external axes are connected
to the YRC1000.
Connection for external axis overrun
YRC1000
Safety terminal block board
Safety circuit board
External axis overrun
Turn ON/OFF at the same time
1
9
10
11
12
CN206
CN220
-X18
OT2_1-
OT2_2+
OT2_2-
OT2_1+
2
3
4
5
Summary of Contents for YRC1000
Page 1: ...ROBOTICS Instructions Robot controller User manual ...
Page 30: ...Supply 3 30 Hood for CEE connector Covers ...
Page 51: ...Connection 5 51 8 Close the YRC1000 door ...
Page 142: ...System Setup 9 142 6 Select YES All data of the interference signal number is deleted ...
Page 174: ...System Setup 9 174 7 Press ENTER The speed is modified ...
Page 219: ...System Setup 9 219 4 Select GRAPH The graph appears 4 5 6 7 8 9 10 1 2 3 ...
Page 453: ...Description of Units and Circuit Boards 15 453 ...