Modification of System Configuration
13
-
374
2. Select the connection item of desired control group.
–
The settable items are displayed.
–
Select an item to change the setting. Select {CANCEL} to return to the CONNECT
window.
[CONNECT (STO) window]
–
Specify which connector (CN) of the SERVO board each axis of each control group is
connected to. The numbers in [ ] represent axis numbers, and indicate which axis is
connected to which connector.
–
Specify which brake (BRK) of the contactor unit each axis of each control group is
connected to. The numbers in [ ] represent the axis numbers, and indicate which axis
is connected to which brake.
–
Specify which converter (CV) each axis of each control group is connected to. The
numbers in [ ] represent the converter numbers, and indicate which axis is connected
to which converter.
–
Specify with which enabling signal (ON_EN) the control group is connected.
–
Specify which overrun signal (OT) each control group is connected to.
[CONNECT (CONTACTOR) window]
–
Specify which connector (CN) of the SERVO board each axis of each control group is
connected to. The numbers in [ ] represent axis numbers, and indicate which axis is
connected to which connector.
–
Specify which break (BRK) of the contactor unit each axis of each control group is
connected to. The numbers in [ ] represent the axis numbers, and indicate which axis
is connected to which break.
–
Specify which converter (CV) each axis of each control group is connected to. The
numbers in [ ] represent the converter numbers, and indicate which axis is connected
to which converter.
–
Specify which overrun signal (OT) each control group is connected to.
–
In this example, B1 (Base) is connected in the following manner:
1. Axis
→
SERVO board (SV #2),
Connector (7CN),
Contactor unit (TU #1),
Brake connector (BRK7)
Converter (CV #1)
2. Axis
→
SERVO board (SV #2),
Connector (8CN)
Contactor unit (TU #1),
Brake connector (BRK8)
Converter (CV #2)
Summary of Contents for YRC1000
Page 1: ...ROBOTICS Instructions Robot controller User manual ...
Page 30: ...Supply 3 30 Hood for CEE connector Covers ...
Page 51: ...Connection 5 51 8 Close the YRC1000 door ...
Page 142: ...System Setup 9 142 6 Select YES All data of the interference signal number is deleted ...
Page 174: ...System Setup 9 174 7 Press ENTER The speed is modified ...
Page 219: ...System Setup 9 219 4 Select GRAPH The graph appears 4 5 6 7 8 9 10 1 2 3 ...
Page 453: ...Description of Units and Circuit Boards 15 453 ...