9.26.17.2 Safety flash data erase or reset
A safety logic circuit file written in the FLASH ROM of the safety circuit board can be
cleared. After erasing, a safety logic circuit file can be transferred to the safety circuit board
and written in the FLASH ROM.
These clear/reset operations are explained in the following.
Safety circuit board FLASH erase
1. Displaying the window.
Select {Machine Safety Board FLASH Erase} by going to {INITIALIZE} from {FILE} in
the man menu.
The confirmation dialog appears, and select {YES}.
The safety logic circuit file written in the FLASH ROM of the safety circuit board is
cleared.
NOTICE
After performing the “Safety circuit board FLASH erase”, and turning the YRC1000power
supply ON/OFF. Next time when turning the power supply ON, the alarm “0300: VERIFY
ERROR (SYSTEM CONFIG-DATA)” occurs. Therefore, when performing the “Machine
safety board FLASH erase”, the “Safety FLASH restart” needs to be performed as well.
Safety FLASH reset
1. Displaying the window.
Select {Safety board FLASH reset} by going to {INITIALIZE} from {FILE} in the man
menu.
The confirmation dialog appears, and select {YES}.
The safety logic circuit file (file name: YSFLOGIC.DAT) is transferred and written in the
FLASH ROM of the machine safety circuit board (type: YSF21-E).
Summary of Contents for YRC1000
Page 1: ...ROBOTICS Instructions Robot controller User manual ...
Page 30: ...Supply 3 30 Hood for CEE connector Covers ...
Page 51: ...Connection 5 51 8 Close the YRC1000 door ...
Page 142: ...System Setup 9 142 6 Select YES All data of the interference signal number is deleted ...
Page 174: ...System Setup 9 174 7 Press ENTER The speed is modified ...
Page 219: ...System Setup 9 219 4 Select GRAPH The graph appears 4 5 6 7 8 9 10 1 2 3 ...
Page 453: ...Description of Units and Circuit Boards 15 453 ...