E.3 User Setting Table
620
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
L3-41
Vibration Suppression Gain during Deceleration (with
Current Limit)
L3-44
Current-limited Integral Time Constant during
Deceleration
L3-45
Current-limited Maximum S-curve Selection during
Deceleration
L4-01
Speed Agreement Detection Level
L4-02
Speed Agreement Detection Width
L4-03
Speed Agreement Detection Level (+/-)
L4-04
Speed Agreement Detection Width (+/-)
L4-05
Frequency Reference Loss Detection Selection
L4-06
Frequency Reference at Reference Loss
L4-07
Speed Agree Detection Selection
L5-01
Number of Auto Restart Attempts
L5-02
Auto Restart Fault Output Operation Selection
L5-04
Fault Reset Interval Time
L5-05
Fault Reset Operation Selection
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L6-04
Torque Detection Selection 2
L6-05
Torque Detection Level 2
L6-06
Torque Detection Time 2
L6-08
Mechanical Weakening Detection Operation
L6-09
Mechanical Weakening Detection Speed Level
L6-10
Mechanical Weakening Detection Time
L6-11
Mechanical Weakening Detection Start Time
L7-01
Forward Torque Limit
L7-02
Reverse Torque Limit
L7-03
Forward Regenerative Torque Limit
L7-04
Reverse Regenerative Torque Limit
L7-06
Torque Limit Integral Time Constant
L7-07
Torque Limit Control Method Selection during Accel/
Decel
L7-16
Torque Limit Process at Start
L8-02
Overheat Alarm Level
L8-07
Output Phase Loss Protection
L8-09
Output Ground Fault Detection Selection
L8-10
Heatsink Cooling Fan Operation Selection
L8-11
Heatsink Cooling Fan Off Delay Time
L8-12
Ambient Temperature Setting
L8-15
oL2 Characteristics Selection at Low Speeds
L8-18
Software Current Limit Selection
L8-19
Frequency Reduction Rate during Overheat Pre-Alarm
L8-27
Overcurrent Detection Gain
L8-29
Current Unbalance Detection (LF2)
L8-32
Cooling Fan Failure Selection
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
L8-40
Carrier Frequency Reduction Off-Delay Time
L8-41
High Current Alarm Selection
L8-93
LSo Detection Time at Low Speed
L8-94
LSo Detection Level at Low Speed
L8-95
Average LSo Frequency at Low Speed
L9-03
Carrier Frequency Reduction Level Selection
L9-12
SoH Alarm Selection during bb
n1-01
Hunting Prevention Selection
n1-02
Hunting Prevention Gain Setting
n1-03
Hunting Prevention Time Constant
n1-05
Hunting Prevention Gain while in Reverse
n1-09
Vibration Suppression Level
n1-10
Suppression Frequency
n1-11
Suppression Auxiliary Frequency
n1-12
Vibration Suppression Time Constant
n2-01
Speed Feedback Detection Control (AFR) Gain
n2-02
Speed Feedback Detection Control (AFR) Time Constant 1
No.
Name
User
Setting
n3-13
Overexcitation Deceleration Gain
n5-01
Feed Forward Control Selection
n5-02
Motor Acceleration Time
n5-03
Feed Forward Control Gain
n6-01
Online Tuning Selection
n6-05
Online Tuning Gain
n8-01
Initial Rotor Position Estimation Current
n8-02
Pole Attraction Current
n8-11
Induction Voltage Estimation Gain 2
n8-14
Polarity Compensation Gain 3
n8-15
Polarity Compensation Gain 4
n8-21
Motor Ke Gain
n8-35
Initial Rotor Position Detection Selection
n8-36
High Frequency Injection Level
n8-37
High Frequency Injection Amplitude
n8-39
Low Pass Filter Cutoff Frequency for High Frequency
Injection
n8-45
Speed Feedback Detection Control Gain (for PM Motors)
n8-47
Pull-In Current Compensation Time Constant (for PM
Motors)
n8-48
Pull-In Current (for PM Motors)
n8-49
d-Axis Current for High Efficiency Control (for PM
Motors)
n8-51
Acceleration/Deceleration Pull-In Current (for PM Motors)
n8-54
Voltage Error Compensation Time Constant
n8-55
Load Inertia
n8-57
High Frequency Injection
n8-62
Output Voltage Limit (for PM Motors)
n8-63
Output Voltage Limit Proportional Gain (for PM Motors)
n8-64
Output Voltage Limit Integral Time (for PM Motors)
n8-66
Output Voltage Limit Output Filter Time Constant (for PM
Motors)
n8-69
Speed Calculation Gain
n8-72
Speed Estimation Method Selection
n8-84
Polarity Judge Current
o1-01
Drive Mode Unit Monitor Selection
o1-02
User Monitor Selection After Power Up
o1-03
Digital Operator Display Selection
o1-04
V/f Pattern Display Unit
o1-05
LCD Contrast Control
o1-10
User-Set Display Units Maximum Value
o1-11
User-Set Display Units Decimal Display
o2-01
LO/RE (LOCAL/REMOTE) Key Function Selection
o2-02
STOP Key Function Selection
o2-03
User Parameter Default Value
o2-04
Drive Model Selection
o2-05
Frequency Reference Setting Method Selection
o2-06
Operation Selection when Digital Operator is
Disconnected
o2-07
Motor Direction at Power Up when Using Operator
o3-01
Copy Function Selection
o3-02
Copy Allowed Selection
o4-01
Cumulative Operation Time Setting
o4-02
Cumulative Operation Time Selection
o4-03
Cooling Fan Maintenance Operation Time Setting
o4-05
Capacitor Maintenance Setting
o4-07
DC Bus Pre-charge Relay Maintenance Setting
o4-11
U2, U3 Initialize Selection
o4-12
kWh Monitor Initialization
o4-13
Number of Run Commands Counter Initialization
o4-19
Power Unit Price
q1-01 to
q6-07
DriveWorksEZ Parameters
r1-01 to
r1-40
DriveWorksEZ Connection Parameter 1 to 20 (upper/
lower)
T1-00
Motor 1/Motor 2 Selection
T1-01
Auto-Tuning Mode Selection
No.
Name
User
Setting
SIEP_C710636_02B_1_0.book 620 ページ 2015年11月25日 水曜日 午後4時56分