![YASKAWA U1000 Series Technical Manual Download Page 543](http://html.mh-extra.com/html/yaskawa/u1000-series/u1000-series_technical-manual_907114543.webp)
B.7 Parameters that Change with the Motor Code Selection (for PM Motors)
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
543
Par
ame
te
r Li
s
t
B
B.7
Parameters that Change with the Motor Code Selection (for PM Motors)
The following tables show parameters and default settings that change with the motor code selection E5-01 when Open
Loop Vector for PM motors is used.
◆
YASKAWA SMRA Series SPM Motor
Table B.11 200 V, 1800 min
-1
Type YASKAWA SMRA Series SPM Motor
Table B.12 200 V, 3600 min
-1
Type YASKAWA SMRA Series SPM Motor
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM Motors)
−
0002
0003
0005
0006
0008
Voltage Class
V
200
200
200
200
200
Rated Power
kW
0.4
0.75
1.5
2.2
3.7
Rated Speed
min
-1
1800
1800
1800
1800
1800
E5-02
Motor Rated Power (for PM Motors)
kW
0.4
0.75
1.5
2.2
3.7
E5-03
Motor Rated Current (for PM Motors)
A
2.1
4.0
6.9
10.8
17.4
E5-04
Number of Motor Poles (for PM Motors)
–
8
8
8
8
8
E5-05
Motor Stator Resistance (r1) (for PM Motors)
Ω
2.47
1.02
0.679
0.291
0.169
E5-06
Motor d-Axis Inductance (Ld) (for PM
Motors)
mH
12.7
4.8
3.9
3.6
2.5
E5-07
Motor q-Axis Inductance (Lq) (for PM
Motors)
mH
12.7
4.8
3.9
3.6
2.5
E5-09
Motor Induction Voltage Constant 1 (Ke) (for
PM Motors)
mVs/rad
0
0
0
0
0
E5-24
Motor Induction Voltage Constant 2 (Ke) (for
PM Motors)
mV/(min
-1
)
62.0 64.1 73.4 69.6 72.2
E1-04
Maximum Output Frequency
Hz
120
120
120
120
120
E1-05
Maximum
Voltage
V
200.0 200.0 200.0 200.0 200.0
E1-06
Base Frequency
Hz
120
120
120
120
120
E1-09
Minimum Output Frequency
Hz
6
6
6
6
6
C5-17
Motor Inertia
kgm
2
0.0007 0.0014 0.0021 0.0032 0.0046
n5-02
Motor Acceleration Time
s
0.064
0.066
0.049
0.051
0.044
n8-49
d-Axis Current for High Efficiency Control
(for PM Motors) (OLV/PM)
%
0
0
0
0
0
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM Motors)
−
0103
0105
0106
0108
Voltage Class
V
200
200
200
200
Rated Power
kW
0.75
1.5
2.2
3.7
Rated Speed
min
-1
3600
3600
3600
3600
E5-02
Motor Rated Power (for PM Motors)
kW
0.75
1.5
2.2
3.7
E5-03
Motor Rated Current (for PM Motors)
A
4.1
8.0
10.5
16.5
E5-04
Number of Motor Poles (for PM Motors)
–
8
8
8
8
E5-05
Motor Stator Resistance (r1) (for PM Motors)
Ω
0.538
0.20 0.15 0.097
E5-06
Motor d-Axis Inductance (Ld) (for PM
Motors)
mH
3.2
1.3
1.1
1.1
E5-07
Motor q-Axis Inductance (Lq) (for PM
Motors)
mH
3.2
1.3
1.1
1.1
E5-09
Motor Induction Voltage Constant 1 (Ke) (for
PM Motors)
mVs/rad
0
0
0
0
E5-24
Motor Induction Voltage Constant 2 (Ke) (for
PM Motors)
mV/(min
-1
)
32.4 32.7 36.7 39.7
E1-04
Maximum Output Frequency
Hz
240
240
240
240
E1-05
Maximum
Voltage
V
200.0 200.0 200.0 200.0
E1-06
Base Frequency
Hz
240
240
240
240
E1-09
Minimum Output Frequency
Hz
12
12
12
12
C5-17
Motor Inertia
kgm
2
0.0007 0.0014 0.0021 0.0032
n5-02
Motor Acceleration Time
s
0.137
0.132
0.132
0.122
n8-49
d-Axis Current for High Efficiency Control
(for PM Motors) (OLV/PM)
%
0
0
0
0
SIEP_C710636_02B_1_0.book 543 ページ 2015年11月25日 水曜日 午後4時56分