![YASKAWA U1000 Series Technical Manual Download Page 447](http://html.mh-extra.com/html/yaskawa/u1000-series/u1000-series_technical-manual_907114447.webp)
8.4 Option Card Installation
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
447
P
er
ip
h
er
al
Dev
ices
&
Op
ti
o
n
s
8
Wire Gauges and Tightening Torques
Wire gauge and torque specifications are listed in
. For simpler and more reliable wiring, use crimp ferrules on
the wire ends. Refer to the option manuals for the wire size and torque specifications of other options.
Table 8.10 Wire Gauges and Tightening Torques
Crimp Terminals
Yaskawa recommends using CRIMPFOX 6 by Phoenix Contact or equivalent crimp terminals with the specifications
listed in
for wiring to ensure proper connections.
Note:
Properly trim wire ends so loose wire ends do not extend from the crimp terminals.
Table 8.11 Crimp Terminal Sizes
6.
Route the option wiring.
Route the wiring inside the enclosure as shown in
Figure 8.13
Figure 8.15 Wire Routing Examples
Terminal Signal
Screw
Size
Tightening Torque
N
m
(in
lb)
Bare Cable
Crimp Terminals
Wire Type
Recomm. Gauge
mm
2
Applicable Gauges
mm
2
Recomm. Gauge
mm
2
Applicable Gauges
mm
2
A+, A–, B+,
B–, Z+, Z–,
SD, FE, IP, IG
M2
0.22 to 0.25
(1.95 to 2.21)
0.75
(18 AWG)
Stranded wire:
0.25 to 1.0
(24 to 17 AWG)
Solid wire:
0.25 to 1.5
(24 to 16 AWG)
0.5
(20 AWG)
0.25 to 0.5
(24 to 20 AWG)
Shielded twisted
pair, etc.
a+, a–, b+,
b–, z+, z–, SG
Shielded cable,
etc.
Wire Gauge
mm
2
Phoenix Contact Model
L
mm (in)
d1
mm (in)
d2
mm (in)
0.25 (24 AWG)
AI 0.25-6YE
10.5 (13/32)
0.8 (1/32)
2 (5/64)
0.34 (22 AWG)
AI 0.34-6TQ
10.5 (13/32)
0.8 (1/32)
2 (5/64)
0.5 (20 AWG)
AI 0.5-6WH
14 (9/16)
1.1 (3/64)
2.5 (3/32)
d1
d2
6 mm
L
SIEP_C710636_02B_1_0.book 447 ページ 2015年11月25日 水曜日 午後4時56分