A.3 Three-Phase 400 V Class Drives
A.3 Three-Phase 400 V Class Drives
Table A.3 Power Ratings (Three-Phase 400 V Class)
Item
Specification
CIMR-U
4
0011
0014
0021
0027
0034
0040
0052
0065
0077
0096
0124
0156
Input/
Output
Rating
Input Current (A)
HD Rating
8.7
10
13
19
25
31
36
47
59
70
87
113
ND Rating
10
13
19
25
31
36
47
59
70
87
113
142
Rated Input Capacity (kVA)
HD Rating
8
9
12
17
22
28
33
43
54
64
80
103
ND Rating
9
12
17
22
28
33
43
54
64
80
103
130
Rated Output Current
(A)
HD Rating
9.6
11
14
21
27
34
40
52
65
77
96
124
ND Rating
11
14
21
27
34
40
52
65
77
96
124
156
Overload Tolerance
HD Rating: 150% of rated output current for 60 s
ND Rating: 120% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
4 kHz (User adjustable up to 10 kHz. Derating may be required.)
Maximum Output Voltage (V)
Proportional to input voltage
Maximum Output Frequency (Hz)
400 Hz
Power
Supply
Rated Voltage Rated Frequency
Three-phase (CIMR-U
4A
/4P
) 380 to 500 Vac 50/60 Hz
Three-phase (CIMR-U
4E
/4W
) 380 to 480 Vac 50/60 Hz
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency Fluctuation
±
3% (Frequency fluctuation rate: 1 Hz/100 ms or less)
Allowable Phase Power Supply Voltage
Unbalance
2% or less
Harmonic Current Harmonic Distortion
5% or less (IEEE519 compliant)
Input Power Factor
0.98% or more (During rated operation)
Item
<1> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring
connections, and power supply impedance.
<2> Rated input capacity is calculated with a power line voltage of 480 V
×
1.1.
<3> The rated output current of the drive output amps should be equal to or greater than the motor rated current.
<4> Carrier frequency is set to 4 kHz for models CIMR-U
4
0011 to 4
0414. Carrier frequency is set to 3 kHz for models CIMR-U
4
0477
to 4
0930. Current derating is required in order to raise the carrier frequency.
<5> If the harmonic current distortion is needed to be 5% or less, the maximum output voltage will be the equivalent to the input voltage
×
0.87.
C7-60 (Output Voltage Limit Mode Selection) is needed to be changed from the default setting.
<6> User-adjustable
<7> Use a stand-alone EMC filter with a voltage of 380 to 480 V for models CIMR-U
4
0477 to 4
0930.
Specification
CIMR-U
4
0180
0216
0240
0302
0361
0414
0477
0590
0720
0900
0930
Input/
Output
Rating
Input Current (A)
HD Rating
142
164
197
218
275
329
377 434 537 655 819
ND Rating
164
197
218
275
329
377
434 537 655 819 846
Rated Input Capacity (kVA)
HD Rating
130
150
180
200
251
300
344 396 490 598 748
ND Rating
150
180
200
251
300
344
396 490 598 748 773
Rated Output Current
(A)
HD Rating
156
180
216
240
302
361
414 477 590 720 900
ND Rating
180
216
240
302
361
414
477 590 720 900 930
Overload Tolerance
HD Rating: 150% of rated output current for 60 s
ND Rating: 120% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
4 kHz (User adjustable up to 6 kHz. Derating may be required.)
3 kHz
Maximum Output Voltage (V)
Proportional to input voltage
Maximum Output Frequency (Hz)
400 Hz
Power
Supply
Rated Voltage Rated Frequency
Three-phase (CIMR-U
4A
/4P
) 380 to 500 Vac
50/60 Hz
Three-phase (CIMR-U
4E
/4W
) 380 to 480 Vac 50/60 Hz
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency Fluctuation
±
3% (Frequency fluctuation rate: 1 Hz/100 ms or less)
Allowable Phase Power Supply Voltage
Unbalance
2% or less
Harmonic Current Harmonic Distortion
5% or less (IEEE519 compliant)
Input Power Factor
0.98% or more (During rated operation)