![YASKAWA U1000 Series Technical Manual Download Page 275](http://html.mh-extra.com/html/yaskawa/u1000-series/u1000-series_technical-manual_907114275.webp)
5.7 H: Terminal Functions
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
275
5
parameters.
Note: 1.
The Up 2 and Down 2 functions must be set as a pair.
2.
When using the Up 2 and Down 2, set appropriate bias limit values to parameters d4-08 and d4-09.
Table 5.39 Up/Down 2 Operations
Setting 77: ASR gain switch
Switches the ASR gain between the values set to C5-01 and C5-03. The gain set to C5-03 is enabled when the terminal is
closed, and C5-01 is enabled when the terminal opens again.
Refer to C5-01, C5-03/C5-02, C5-04: ASR Proportional
Gain 1, 2 / ASR Integral Time 1, 2 on page 224
for a more detailed description.
Setting 78: External torque reference polarity inversion
Reverses the direction of the torque reference when the terminal closes. Refer to
d5: Torque Control on page 238
and
Setting the Torque Reference, Speed Limit, and Torque Compensation Values on page 239
for details.
Setting 7E: Forward/reverse detection (for V/f Control with Simple PG Feedback)
When a digital input is programmed for this function, the input determines the motor rotation direction for V/f Control
with Simple PG feedback (A1-02 = 0 and H6-01 = 3). If the input is open, the speed feedback signal is considered to be
forward. If the input is closed, it is considered to be in reverse.
Refer to H6: Pulse Train Input/Output on page 293
.
Setting 90 to 97: DriveWorksEZ Digital Input 1 to 8
These settings are for digital inputs functions used in DriveWorksEZ. Normally there is no need to change these settings.
Setting 9F: DriveWorksEZ Disable
This function is used to enable or disable a DriveWorksEZ program in the drive. An input programmed for this function
is effective only if A1-07 = 2.
Condition
Freq. Ref. Source
d4-03
d4-05
d4-01
Operation
Frequency Saved
1
Multi-Step Speed
Reference
0
0
0
• Accelerates (increases the bias) while the Up 2 terminal is closed.
• Decelerates (decreases the bias) while Down 2 is closed.
• Holds output frequency (holds the bias) when no Up 2 or Down 2
command or both active.
• Resets the bias when the reference changes.
• Operates with the frequency reference in all other situations.
Not saved
2
1
If the bias and frequency reference are
constant for 5 s, the bias is added to the
active frequency reference and reset
afterwards.
3
1
–
• Accelerates (increases the bias) while the Up 2 terminal is closed.
• Decelerates (decreases the bias) while Down 2 is closed.
• Otherwise operates at the frequency reference.
Not saved
4
Multi-Step Speed
Reference
Value other
than 0
–
0
• When the Up 2 is enabled, drive accelerates up to the frequency
reference plus d4-03 (bias is increased for d4-03).
• When Down 2 is enabled, drive decelerates down to the
frequency reference minus d4-03 (bias is decreased for d4-03).
• Holds output frequency (holds the bias) when no Up 2 or Down 2
input or both active.
• Resets the bias when the reference changes.
• Operates with the frequency reference in all other situations.
Not saved
5
1
If the bias and frequency reference are
constant for 5 s, the bias is added to the
active frequency reference and reset
afterwards.
6
Other
(analog comm., etc.)
0
0
0
• Accelerates (increases the bias) while the Up 2 terminal is closed.
• Decelerates (decreases the bias) while Down 2 is closed.
• Holds output frequency (holds the bias) when no Up 2 or Down 2
input or both active.
• If the frequency reference changes for more than d4-07 during
accel/decel, bias value is held until the output frequency meets
the reference (speed agree).
Not saved
7
1
If the bias is constant for 5 s, it is saved to
parameter d4-06. The frequency reference
cannot be overwritten, so only the bias is
saved.
8
Other
(analog comm, etc.)
0
1
–
• Accelerates (increases the bias) while the Up 2 terminal is closed.
• Decelerates (decreases the bias) while Down 2 is closed.
• Otherwise operates at the frequency reference
Not saved
9
Value other
than 0
–
0
• When Up 2 is enabled, drive accelerates up to the frequency
reference plus d4-03 (increases the bias for d4-03).
• When Down 2 is enabled, drive decelerates down to the
frequency reference minus d4-03 (decreases the bias for d4-03).
• If the frequency reference changes for more then d4-07 during
accel/decel, bias value is held until the output frequency meets
the reference (speed agree).
Not saved
10
1
If the bias is constant for 5 s, it is saved to
parameter d4-06. The frequency reference
cannot be overwritten, so only the bias is
saved.
Status
Description
Open
DriveWorksEZ enabled
Closed
DriveWorksEZ disabled
SIEP_C710636_02B_1_0.book 275 ページ 2015年11月25日 水曜日 午後4時56分