![YASKAWA U1000 Series Technical Manual Download Page 410](http://html.mh-extra.com/html/yaskawa/u1000-series/u1000-series_technical-manual_907114410.webp)
7.4 Cooling Fan and Circulation Fan
410
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
Removing the Circulation Fan Unit
CAUTION!
Crush Hazard. Do not completely remove the cover screws, just loosen them. If the cover screws are removed completely,
the terminal cover may fall off causing an injury. Take special care when removing/reattaching the terminal covers for larger drives.
1.
Loosen the five screws that hold the drive cover in place and free it from the drive.
Figure 7.32
Figure 7.32 Remove the Drive Cover
2.
Unlock the two cable hooks.
Note:
The circulation fan unit on models 4
0302 to 4
0414 is located on the right side of the drive.
Figure 7.33
Figure 7.33 Unlock the Cable Hooks
3.
Unplug the relay connectors and free the cable from the hooks.
Figure 7.34
Figure 7.34 Unplug the Relay Connector
Five-screw locations
SIEP_C710636_02B_1_0.book 410 ページ 2015年11月25日 水曜日 午後4時56分