1.2 General Description
Re
ce
iv
in
g
1
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
31
1.2 General Description
◆
U1000 Model Selection
for drive selection depending on Normal Duty (ND) or Heavy Duty (HD) rating.
Note:
The models and capacities in shown here are based on standard settings and operation conditions. Higher carrier frequencies and
higher ambient temperatures require derating.
Table 1.1 U1000 Models
Note:
Current derating is required when setting the carrier frequency higher.
Refer to Carrier Frequency Derating on page 462
details.
3-Phase 200 V Class
3-Phase 400 V Class
Model
CIMR-U
Heavy Duty Rating (HD)
Normal Duty Rating (ND)
Model
CIMR-U
Heavy Duty Rating (HD)
Normal Duty Rating (ND)
Rated Output
Current (A)
Rated Output
Current (A)
Rated Output
Current (A)
Rated Output
Current (A)
2
0028
22
28
4
0011
9.6
11
2
0042
28
42
4
0014
11
14
2
0054
42
54
4
0021
14
21
2
0068
54
68
4
0027
21
27
2
0081
68
81
4
0034
27
34
2
0104
81
104
4
0040
34
40
2
0130
104
130
4
0052
40
52
2
0154
130
154
4
0065
52
65
2
0192
154
192
4
0077
65
77
2
0248
192
248
4
0096
77
96
–
–
–
4
0124
96
124
–
–
–
4
0156
124
156
–
–
–
4
0180
156
180
–
–
–
4
0216
180
216
–
–
–
4
0240
216
240
–
–
–
4
0302
240
302
–
–
–
4
0361
302
361
–
–
–
4
0414
361
414
–
–
–
4
0477
414
477
–
–
–
4
0590
477
590
–
–
–
4
0720
590
720
–
–
–
4
0900
720
900
–
–
–
4
0930
900
930