Table 6.10 Fault Displays (2)
Digital Operator Display
Name
Page
Digital Operator Display
Name
Page
LED Operator
LCD Operator
LED Operator
LCD Operator
oFb01
Option Card Fault at Option Port CN5-B
oL5
Mechanical Weakening Detection 1
oFb02
Option Card Fault at Option Port CN5-B
oPr
External Digital Operator Connection Fault
,
oFb03, oFb11
Option Card Error Occurred at Option Port
CN5-B
oS
Overspeed
to
oFb12 to oFb17
Option Card Error Occurred at Option Port
CN5-B
ov
Control Circuit Overvoltage
PGo
PG Disconnect (for Control Mode with PG)
oFC00
Option Card Connection Error at Option
Port CN5-C
PGoH
PG Hardware Fault (when using PG-X3)
oFC01
Option Card Fault at Option Port CN5-C
SCF
Safety Circuit Fault
oFC02
Option Card Fault at Option Port CN5-C
SEr
Too Many Speed Search Restarts
,
<1> Displayed as CPF00 or CPF20 when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display
will show CPF01 or CPF21.
<2> This function prevents continuous operation in reverse when using high frequency injection (n8-57 = 1) in the Advanced Open Loop Vector
Control mode for PM motors (A1-02 = 6) with a motor for which no motor code has been entered (it does not simply prevent reverse
operation). To quickly detect undesirable reverse operation, set L8-93, L8-94, and L8-95 to low values within range of erroneous detection.
<3> Fault trace (i.e., the fault history) is not kept when CPF00, CPF01, CPF06, CPF24, Fdv, oFA00, oFb00, oFC00, Uv1, Uv2, and Uv3 occur.
oFC03, oFC11
Option Card Error Occurred at Option Port
CN5-C
SoH
Snubber Discharge Resistor Overheat
SrC
Phase Order Detection Fault
to
oFC12 to oFC17
Option Card Error Occurred at Option Port
CN5-C
Srr
Internal Resistance Fault
to
oFC50 to oFC55
Option Card Error Occurred at Option Port
CN5-C
STo
Pull-Out Detection
oH
Heatsink Overheat
SvE
Zero Servo Fault
oH1
Overheat 1 (Heatsink Overheat)
UL3
Undertorque Detection 1
oH3
Motor Overheat Alarm (PTC Input)
UL4
Undertorque Detection 2
oH4
Motor Overheat Fault (PTC Input)
UL5
Mechanical Weakening Detection 2
oL1
Motor Overload
Uv1
Control Circuit Undervoltage Fault
oL2
Drive Overload
Uv2
Control Power Supply Voltage Fault
oL3
Overtorque Detection 1
Uv3
Undervoltage 3 (Soft-Charge Bypass
Circuit Fault)
oL4
Overtorque Detection 2
–
–
–
–
SIEP_C710636_02B_1_0.book 350 ページ 2015年11月25日 水曜日 午後4時56分