Alar
m List
Alar
m Nu
mbe
r (4
00
0 to
4
9
99
)
Alarm List-657
7
Error from welder 7.
Arc welding power source
error
Contact your Yaskawa representative.
8
Error from welder 8.
Arc welding power source
error
Contact your Yaskawa representative.
101
Sub code: Error No. from
welder.
Arc welding power source
error
Contact your Yaskawa representative.
4273
MOTOWELD IGBT
SHORT CIRCUIT
1
Error from welder 1.
Arc welding power source
error
Replace the IGBT device (Part code AJ0EL3870).
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2
Error from welder 2.
Arc welding power source
error
Replace the IGBT device (Part code AJ0EL3870).
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
3
Error from welder 3.
Arc welding power source
error
Replace the IGBT device (Part code AJ0EL3870).
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4
Error from welder 4.
Arc welding power source
error
Replace the IGBT device (Part code AJ0EL3870).
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
5
Error from welder 5.
Arc welding power source
error
Replace the IGBT device (Part code AJ0EL3870).
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
6
Error from welder 6.
Arc welding power source
error
Replace the IGBT device (Part code AJ0EL3870).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy