JL012 data setting error.
Communication error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, check the connection and inserting state
of the following cable.
∙
The communications cable for the I/O module
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
-23
DeviceNet response error.
Communication error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, check the connection and inserting state
of the following cable.
∙
The communications cable for the DeviceNet
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
-24
NADEX data sheet format
error.
Software operation error
occurred
The connected NADEX spot welder isn't corresponded to.Save the
CMOS.BIN in maintenance mode, and then contact your Yaskawa
representative about occurrence status (operating procedure).
-25
JL012 data overflow.
Communication error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, check the connection and inserting state
of the following cable.
∙
The communications cable for the I/O module
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
-100
Initialization error.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
-102
Not found the spot welder
number.
Setting error
Check the following settings.
∙
The parameter "AxP003:The maximum number of connected spot
welders".
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy