11
LED Indicator on Circuit Board
11.4 LED Indicator
11-9
11.4
LED Indicator
The following tables show the operating statues for SRDA-EAXA21/
JANCD-YSF21.
Table 11-3: [Normal indication]
Status
DX200
EAXA21
YSF21
Right after
applying the
power
All indicators light up.
All indicators light up.
During the
start-up
process
{Normal status} : D22,D23,D40 (green) light up
*Lighting the LED changes according to the
activation process.
{Detected error} : D48 (red) blink
{Normal status} : D2, D7 (green) blink
*Lighting the LED changes according to the
activation process.
{Detected error} : D5, D10 (red) blink
After starting
up normally
{Normal status} : D22 (green) blink
{Detected an alarm} : D48 (red) blink
{Normal status} : D2,D7 (green) blink
{Detected minor alarm} : D5, D10 (red) blink
{Detected major alarm} : D5, D10
(red) light up