Alar
m List
Alar
m Nu
mbe
r (0
00
0 to
0
9
99
)
Alarm List-175
Software operation error
occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
0936
CPU HANG UP
ERROR(YCP02#6)
An error was detected in the
CPU.
Setting error
(1)Check the following settings.
∙
Optional board in maintenance mode
YCP02 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the following board. Save the
CMOS.BIN before replace the board to be safe.
∙
YCP02 board
YCP21 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then remove the CF from the failure YCP21 board to insert
it into the new YCP21 board.
Software operation error
occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
0937
CPU HANG UP
ERROR(YCP02#7)
An error was detected in the
CPU.
Setting error
(1)Check the following settings.
∙
Optional board in maintenance mode
YCP02 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the following board. Save the
CMOS.BIN before replace the board to be safe.
∙
YCP02 board
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy