Ala
rm L
ist
Ala
rm
Numb
er
(
1
00
0 to
19
99)
Alarm List-324
505
Error code received (The first
digit shows the converter No.)
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
∙
EAXA21-CN507,510
∙
EAXB21-CN531,532,533
∙
Converter-CN551,553
∙
EX1SV(External axis servo pack)-CN591,592
Module failure (converter)
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the converter.
EAXA21 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replace the board to be safe.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
506
Receive command error (The
first digit shows the converter
No.)
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
∙
EAXA21-CN507,510
∙
EAXB21-CN531,532,533
∙
Converter-CN551,553
∙
EX1SV(External axis servo pack)-CN591,592
Module failure (converter)
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the converter.
EAXA21 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replace the board to be safe.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause