Alar
m List
Alar
m Nu
mbe
r (4
00
0 to
4
9
99
)
Alarm List-473
10
Analog CH specification or
register specification is not
exist.
Setting error
(1)Reset the alarm.
(2)Check the following settings.
∙
Analog CH specification
∙
Register specification
Analog CH specification or register specification is required.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
11
The number of samplings
exceeds the set value.
Setting error
(1)Reset the alarm.
(2)Check the following settings.
∙
The number of samplings
The number of sampling is too much. Confirm the monitor ON/OFF
status.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4129
TWIN DRIVE OUT OF
RANGE (START)
Sub Code: Corresponding
master-axes and slave-axes
are displayed by the bit.
Setting error
(1)Reset the alarm.
(2)Check the following settings.
∙
Pulse error of the master-axes and the slave-axes
Switch to independent movement mode so that the pulse error of the
master-axes and the slave-axes is settled within allowable range.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4130
NETWORK
APPLICATION
PROCESS ERROR
1
An error occurred when the
notification of the APP task re-
initialization was processed in
the Ethernet function.
Software operation error
occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
YCP21 board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then insert the CF card which inserted original YCP21
board into the new YCP21 board.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy