Ala
rm L
ist
Ala
rm
Numb
er
(
4
00
0 to
49
99)
Alarm List-546
6
Unused position data file is
destroyed.
Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(4)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
7
Unused position data file does
not exist.
Setting error
(1)Check the following settings.
∙
The number of steps in job (position data)
Delete unnecessary position data in job and add new position data.
Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(4)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
8
Position data file is destroyed. Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(4)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy