SP bank
Bank selection:
6-4
Chapter 6. LIST OF DISPLAYS AND SETTING DATA
Display
Item
Contents
Initial
value
User
level
Remarks
RSP
—
0
Setting is disabled.
Displayed when the optional
model provides the RSP
input.
PID group No. (For
RSP)
1
1
1 to 8
Displayed when the optional
model provides the RSP
input, the control is other
than ON/OFF control
(CtrL
≠
0), and the zone PID is
not used (C24=0).
SP of LSP 1 group
0
0
SP low limit (C07) to SP high limit
(C08)
PID group No. (For
LSP1)
1
1
1 to 8
Displayed when the control is
other than ON/OFF control
(CtrL
≠
0) and the zone PID is
not used (C24=0).
Ramp (For LSP1)
0
1
0 to 9999 (The decimal point position
is determined by the decimal point
position of PV and the SP ramp unit.)
Displayed when the SP ramp
type (C31) is “1” or more.
Time (For LSP1)
0
1
0.0 to 999.9 (The time unit of the step
operation is “0.1s”.)
0 to 9999 (The time unit of the step
operation is “1s” or “1min”.)
Displayed when the SP ramp
type (C31) is “2” or more.
SP of LSP 2 group
0
0
Same as LSP1 group.
Displayed when the LSP
system group (C30) is “2” or
more and the same
conditions as those for the
LSP1 group are satisfied.
PID group No. (For LSP2)
1
1
Ramp (For LSP2)
0
1
Time (For LSP2)
0
1
SP of LSP 3 group
0
0
Same as LSP1 group.
Displayed when the LSP
system group (C30) is “3” or
more and the same
conditions as those for the
LSP1 group are satisfied.
PID group No. (For LSP3)
1
1
Ramp (For LSP3)
0
1
Time (For LSP3)
0
1
SP of LSP 4 group
0
0
Same as LSP1 group.
Displayed when the LSP
system group (C30) is “4” or
more and the same
conditions as those for the
LSP1 group are satisfied.
PID group No. (For LSP4)
1
1
Ramp (For LSP4)
0
1
Time (For LSP4)
0
1
SP of LSP 5 group
0
0
Same as LSP1 group.
Displayed when the LSP
system group (C30) is “5” or
more and the same
conditions as those for the
LSP1 group are satisfied.
PID group No. (For LSP5)
1
1
Ramp (For LSP5)
0
1
Time (For LSP5)
0
1
SP of LSP 6 group
0
0
Same as LSP1 group.
Displayed when the LSP
system group (C30) is “6” or
more and the same
conditions as those for the
LSP1 group are satisfied.
PID group No. (For LSP6)
1
1
Ramp (For LSP6)
0
1
Time (For LSP6)
0
1
SP of LSP 7 group
0
0
Same as LSP1 group.
Displayed when the LSP
system group (C30) is “7” or
more and the same
conditions as those for the
LSP1 group are satisfied.
PID group No. (For LSP7)
1
1
Ramp (For LSP7)
0
1
Time (For LSP7)
0
1
SP of LSP 8 group
0
0
Same as LSP1 group.
Displayed when the LSP
system group (C30) is “8” or
more and the same
conditions as those for the
LSP1 group are satisfied.
PID group No. (For LSP8)
1
1
Ramp (For LSP8)
0
1
Time (For LSP8)
0
1
Summary of Contents for SDC35
Page 16: ......
Page 17: ......
Page 19: ... display key para key or V key key enter key 2 second press hold of para key V ...
Page 32: ......
Page 46: ......
Page 58: ......
Page 71: ......
Page 84: ......
Page 95: ......
Page 172: ......
Page 174: ...6 2 Chapter 6 LIST OF DISPLAYS AND SETTING DATA ...
Page 211: ......
Page 230: ......
Page 240: ......
Page 248: ......
Page 260: ......
Page 268: ......
Page 270: ......
Page 279: ......