2-10
Physical setup
5
Remove the reservoir cap from each cooling drive, and then fill them
with the supplied distilled water. Ensure that the water level is between
the HIGH and LOW indicators. Then replace the reservoir caps.
HIGH
LOW
Warning:
Only use non-conductive, distilled water. Other liquid can
cause oxidation or corrosive damage to the cooling mechanism.
Note:
Once the remaining setup processes in this chapter are complete,
and the printer power is turned on, check the water level. The water
level may lower due to the liquid entering the printer. It may be
necessary to add more water to the reservoirs.
Note:
During printer operation, the water level must stay between the
HIGH and LOW indicators. If the water level is below the LOW
indicator, the cooling system will become ineffective. It is recommended
that you check the water level periodically and add water if necessary.
Warning:
If the printer will be shipped to another location, it is necessary
to uninstall the water cooling system and purge the remaining water
from the printer.
For more information about uninstalling the water cooling system, refer
to
Chapter 7: Maintenance and Repair
.
Summary of Contents for QLS-8100XE
Page 2: ......
Page 14: ...1 4 Quick start ...
Page 19: ...QLS 8100 Xe 2 5 Side view ...
Page 46: ...3 14 Loading media and calibration ...
Page 149: ...QLS 8100 Xe A 1 Appendix A Physical Data ...
Page 153: ...QLS 8100 Xe B 1 Appendix B Specifications ...
Page 156: ...B 4 Specifications ...
Page 157: ...QLS 8100 Xe C 1 Appendix C Replacement Parts ...
Page 160: ...C 4 Replacement parts ...
Page 161: ...QLS 8100 Xe D 1 Appendix D Color QuickLabel 99 Pro setup ...
Page 166: ...D 6 Color QuickLabel 99 Pro setup ...
Page 167: ...QLS 8100 Xe E 1 Appendix E Windows Printer Driver Setup ...
Page 175: ...QLS 8100 Xe F 1 Appendix F Format error codes ...
Page 180: ...F 6 Format error codes ...
Page 181: ...QLS 8100 Xe G 1 Appendix G Menu Structure ...
Page 182: ...G 2 Menu Structure ...