2-50
Xerox Internal Use Only
Phaser 3010/3040/WorkCentre 3045 Service
Error Troubleshooting
Scanner Maintenance
White Balance
This menu item reports the result of white balance which is performed when
powering up.
Registration Param
This menu item adjusts registration parameters of the scanner.
Auto Registration
This menu item reports the result of auto registration which is performed when
powering up.
IIT I/O Check
Tests Scanner sensors and motors.
Parameter
Range
Description
ADF Lead offset
adjustment
a
a.3-in-1 model does not have an ADF.
-2.0 mm to 2.0 mm
0.1 mm Step
Adjust Registration of ADF
Lead.
ADF Side offset
adjustment
a
-1.0 mm to 1.0 mm
0.1 mm Step
Adjust Registration of ADF
Side.
FB Lead offset
adjustment
-2.0 mm to 2.0 mm
0.1 mm Step
Adjust Registration of FB Lead.
FB Side offset
adjustment
-1.0 mm to 1.0 mm
0.1 mm Step
Adjust Registration of FB Side.
Test
Description
FB Home Sensor
Tests the flatbed home position sensor.
ADF Scan Sensor
a
a.3-in-1 model does not have an ADF.
Tests the ADF scan sensor.
ADF Document Sensor
a
Tests the Feed sensor.
ADF Cover Sensor
a
Tests the ADF cover sensor
Summary of Contents for Phaser 3010
Page 2: ......
Page 22: ...xxii Xerox Internal Use Only Phaser 3010 3040 WorkCentre 3045 Service...
Page 210: ...3 36 Xerox Internal Use Only Phaser 3010 3040 WorkCentre 3045 Service Image Quality...
Page 390: ...6 8 Xerox Internal Use Only Phaser 3010 3040 WorkCentre 3045 Service Maintenance...
Page 419: ...A Appendix Reference In this chapter Using CE Diagnostic Software Acronyms and Abbreviations...
Page 429: ......