PROCEDURE
1
Put the 3/2-way solenoid valve (002,
) in place on the starting air valve (001).
2
Tighten the screws of the 3/2-way solenoid valve (002).
3
Connect the electrical connection to the 3/2-way solenoid valve (002).
Fig 7-54
Starting air valve (example)
CLOSE UP
•
None
X72DF
AA00-2728-00AAB-720A-A
Maintenance Manual
Starting air valve - install the solenoid valve
Winterthur Gas & Diesel Ltd.
- 287 -
Issue 002 2020-10