![WinGD X62DF Maintenance Manual Download Page 745](http://html1.mh-extra.com/html/wingd/x62df/x62df_maintenance-manual_986574745.webp)
PROCEDURE
1
to make sure that there is no pressure in the fuel rail as follows:
1.1
In the plant, set to OFF the fuel booster pump.
1.2
Close the shut-off valves to the fuel inlet and return pipes.
1.3
To release the pressure in the fuel rail, operate the button on the pressure
control valve.
1.4
On the local control panel, make sure that the pressure shows zero.
2
Set to OFF the electrical trace heating system.
3
On the applicable HP fuel pipe, remove the insulation (001,
4
Disconnect the electrical connection (003).
5
Remove the three bolts (004), nuts and washers (005) and the pipe clamp (002).
Fig 13-7
HP Fuel pipe - preparation
002
003
00553
001
001
I
I
I - I
004
002
005
002
CLOSE UP
•
None
X72DF
AA00-8733-00AAA-523A-A
Maintenance Manual
HP fuel pipe (fuel rail to injection valve) - prepare before removal
Winterthur Gas & Diesel Ltd.
- 745 -
Issue 002 2020-10
Summary of Contents for X62DF
Page 881: ...Approved Tightening Instructions Rev I Page 1 14...
Page 882: ...Approved Tightening Instructions Rev I Page 2 14...
Page 883: ...Approved Tightening Instructions Rev I Page 3 14...
Page 884: ...Approved Tightening Instructions Rev I Page 4 14...
Page 885: ...Approved Tightening Instructions Rev I Page 5 14...
Page 886: ...Approved Tightening Instructions Rev I Page 6 14...
Page 887: ...Approved Tightening Instructions Rev I Page 7 14...
Page 888: ...Approved Tightening Instructions Rev I Page 8 14...
Page 889: ...Approved Tightening Instructions Rev I Page 9 14...
Page 890: ...Approved Tightening Instructions Rev I Page 10 14...
Page 891: ...Approved Tightening Instructions Rev I Page 11 14...
Page 892: ...Approved Tightening Instructions Rev I Page 12 14...
Page 893: ...Approved Tightening Instructions Rev I Page 13 14...
Page 894: ...Approved Tightening Instructions Rev I Page 14 14...