![WinGD X62DF Maintenance Manual Download Page 681](http://html1.mh-extra.com/html/wingd/x62df/x62df_maintenance-manual_986574681.webp)
PROCEDURE
1
Examine the cylinder lubricating pump for damage or wear (for example main bore
surface, control edges, injection piston) and for leaks.
2
If damage, wear or leaks occur, repair the fault.
3
Do a check of the non return valves as follows:
3.1
Remove the non return valves.
3.2
Blow air on the non return valves with your mouth.
3.3
If air comes out, clean the valve seat.
3.4
Install the non return valves.
4
Do a function test of the cylinder lubricating system, refer to section
lubrication system - do a functional test
.
CLOSE UP
•
None
X72DF
AA00-7206-00AAA-310A-A
Maintenance Manual
Cylinder lubricating pump (MK-1) - examine
Winterthur Gas & Diesel Ltd.
- 681 -
Issue 002 2020-10
Summary of Contents for X62DF
Page 881: ...Approved Tightening Instructions Rev I Page 1 14...
Page 882: ...Approved Tightening Instructions Rev I Page 2 14...
Page 883: ...Approved Tightening Instructions Rev I Page 3 14...
Page 884: ...Approved Tightening Instructions Rev I Page 4 14...
Page 885: ...Approved Tightening Instructions Rev I Page 5 14...
Page 886: ...Approved Tightening Instructions Rev I Page 6 14...
Page 887: ...Approved Tightening Instructions Rev I Page 7 14...
Page 888: ...Approved Tightening Instructions Rev I Page 8 14...
Page 889: ...Approved Tightening Instructions Rev I Page 9 14...
Page 890: ...Approved Tightening Instructions Rev I Page 10 14...
Page 891: ...Approved Tightening Instructions Rev I Page 11 14...
Page 892: ...Approved Tightening Instructions Rev I Page 12 14...
Page 893: ...Approved Tightening Instructions Rev I Page 13 14...
Page 894: ...Approved Tightening Instructions Rev I Page 14 14...