![WinGD X62DF Maintenance Manual Download Page 213](http://html1.mh-extra.com/html/wingd/x62df/x62df_maintenance-manual_986574213.webp)
14.7
Turn the rod (001) back to release the tension in the spring (006). Make sure
that the valve cotter (003) is installed correctly in the spring carrier (012).
14.8
Remove the dismantling and assembling tool and the bracket from the bush
(007).
15
Do the test procedure given in
again.
16
If the leakage is unsatisfactory, replace the valve spindle and valve guide.
CLOSE UP
•
None
X72DF
AA00-2140-00AAA-362A-A
Maintenance Manual
Gas admission valve - do a check for gas leakage
Winterthur Gas & Diesel Ltd.
- 213 -