PROCEDURE
1
Put a new gasket (006,
) in the bore of the cylinder cover (004).
2
Apply a thin layer of oil to the bore of the cylinder cover (004).
3
Carefully attach the starting air valve (001) to the cylinder cover (004) with the bolts
(003). Make sure that the pipe (005) goes into the bore of the cylinder cover correctly.
4
Torque symmetrically the bolts (003).
5
Connect the electrical connection to the 3/2-way solenoid valve (002).
Fig 7-53
Starting air valve - install
CLOSE UP
•
None
X72DF
AA00-2728-00AAA-720A-A
Maintenance Manual
Starting air valve - install
Winterthur Gas & Diesel Ltd.
- 285 -
Issue 002 2020-10