![WinGD X62DF Maintenance Manual Download Page 195](http://html1.mh-extra.com/html/wingd/x62df/x62df_maintenance-manual_986574195.webp)
PROCEDURE
1
) of the unions.
2
Carefully remove the pipe (002) from the lubricating quill (003).
3
Seal the pipe (002) with an applicable plug to prevent contamination.
4
Remove two the bolts (004).
5
Remove the lubricating quill (003).
6
If necessary, do a function check of the lubricating quills, refer to
.
Fig 7-13
Lubricating quill (example)
CLOSE UP
•
None
X72DF
AA00-2138-00AAA-520A-A
Maintenance Manual
Lubricating quill - remove
Winterthur Gas & Diesel Ltd.
- 195 -
Issue 002 2020-10