Quick Parameter Reference, Faults and Alarms
0-22
0
Parameter
Function
Adjustable Range
Factory Setting
User
Setting
Properties
Groups
Pag.
P0408
Run Self-Tuning
0 = No
1 = No Rotation
2 = Run for I
m
3 = Run for T
m
4 = Estimate T
m
0
CFG, VVW
and Vector
05, 43, 94
P0409
Stator Resistance
0.000 to 9.999 ohm
0.000 ohm
CFG, VVW,
PM and
Vector
05, 43, 94
P0410
Magnetization Current
0 to 1.25xI
nom-ND
I
nom-ND
V/f, VVW
and Vector
05, 43, 94
P0411
Leakage Inductance
0.00 to 99.99 mH
0.00 mH
CFG and
Vector
05, 43, 94
P0412
T
r
Time Constant
0.000 to 9.999 s
0.000 s
Vector
05, 43, 94
P0413
T
m
Time Constant
0.00 to 99.99 s
0.00 s
Vector
05, 43, 94
P0430
Type PM
0 = Factory Setting
1 = Cooling Tower
0
CFG and PM
05, 43, 94
P0431
Pole Number
2 to 24
6
CFG PM
05, 43, 94
P0433
Lq Inductance
0.00 to 100.00 mH
0.00 mH
CFG PM
05, 43, 94
P0434
Ld Inductance
0.00 to 100.00 mH
0.00 mH
CFG PM
05, 43, 94
P0435
Ke Constant
0.0 to 600.0
100.0
CFG PM
05, 43, 94
P0438
Iq Prop. Gain
0.00 to 1.99
0.80
PM
91
P0439
Iq Integral Gain
0.000 to 1.999
0.005
PM
91
P0440
Id Prop. Gain
0.00 to 1.99
0.50
PM
91
P0441
Id Integral Gain
0.000 to 1.999
0.005
PM
91
P0442
Inductance Lq – CT
0.0 to 400.0 mH
0.0 mH
CFG and
PM_CT
05, 43, 94
P0443
Inductance Ld – CT
0.0 to 400.0 mH
0.0 mH
CFG and
PM_CT
05, 43, 94
P0444
Constant Ke – CT
0 to 3000
100
CFG and
PM_CT
05, 43, 94
P0520
PID Proportional Gain
0.000 to 7.999
1.000
-
46
P0521
PID Integral Gain
0.000 to 7.999
0.043
-
46
P0522
PID Differential Gain
0.000 to 3.499
0.000
-
46
P0523
PID Ramp Time
0.0 to 999.0 s
3.0 s
-
46
P0524
PID Feedback Sel.
0 = AI1 (P0231)
1 = AI2 (P0236)
2 = AI3 (P0241)
3 = AI4 (P0246)
1
CFG
38, 46
P0525
Keypad PID Setpoint
0.0 to 100.0 %
0.0 %
-
46
P0527
PID Action Type
0 = Direct
1 = Reverse
0
-
46
P0528
Proc. V. Scale Factor
1 to 9999
1000
-
46
P0529
Proc.V. Decimal Point
0 = wxyz
1 = wxy.z
2 = wx.yz
3 = w.xyz
1
-
46
P0530
Proc. V. Eng. Unit 1
32 to 127
37
-
46
P0531
Proc. V. Eng. Unit 2
32 to 127
32
-
46
P0532
Proc. V. Eng. Unit 3
32 to 127
32
-
46
P0533
PVx Value
0.0 to 100.0 %
90.0 %
-
46
P0534
PVy Value
0.0 to 100.0 %
10.0 %
-
46
P0535
Wake Up Band
0 to 100 %
0 %
-
35, 46
P0536
P0525 Autom. Setting
0 = Off
1 = On
1
CFG
46
P0538
Hysteresis VPx/VPy
0.0 to 5.0 %
1.0 %
-
46
P0550
Trigger Signal Source
0 = Not selected
1 = Speed Refer.
2 = Motor Speed
3 = Motor Current
4 = DC Link Volt.
5 = Motor Freq.
6 = Motor Voltage
7 = Motor Torque
8 = Process Var.
9 = Setpoint PID
10 = AI1
11 = AI2
12 = AI3
13 = AI4
0
-
52
P0551
Trigger Level
-100.0 to 340.0 %
0.0 %
-
52
Summary of Contents for CFW-11 Series
Page 2: ......
Page 54: ...2 4 2 General Information ...
Page 58: ...About the CFW 11 3 3 4 ...
Page 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Page 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Page 94: ...Available Control Types 8 2 8 ...
Page 118: ...VVW Control 10 8 10 ...
Page 182: ...Functions Common to All the Control Modes 12 26 12 ...
Page 220: ...Dynamic Braking 14 4 14 ...