13-21
13
Digital and Analog Inputs and Outputs
Table 13.11 -
Digital output functions
Functions
P0275
(DO1)
P0276
(DO2)
P0277
(DO3)
P0278
(DO4)
P0279
(DO5)
Not Used
0 and 29
0
0
0, 29, 37, 38, 39,
40, 41 and 42
0, 29, 37, 38, 39,
40, 41 and 42
N* > Nx
1
1
1*
1
1
N > Nx
2
2*
2
2
2
N < Ny
3
3
3
3
3
N = N*
4
4
4
4
4
Zero Speed
5
5
5
5
5
Is > Ix
6
6
6
6
6
Is < Ix
7
7
7
7
7
Torque > Tx
8
8
8
8
8
Torque < Tx
9
9
9
9
9
Remote
10
10
10
10
10
Run
11
11
11
11
11
Ready
12
12
12
12
12
No Fault
13*
13
13
13
13
No F070
14
14
14
14
14
No F071
15
15
15
15
15
No F006/021/022
16
16
16
16
16
No F051/054/057
17
17
17
17
17
No F072
18
18
18
18
18
4-20mA Ok
19
19
19
19
19
Value P0695
20
20
20
20
20
Forward
21
21
21
21
21
Process V. > PVx
22
22
22
22
22
Process V. < PVy
23
23
23
23
23
Ride-Through
24
24
24
24
24
Pre-Charge OK
25
25
25
25
25
Fault
26
26
26
26
26
Time Enabled > Hx
27
27
27
27
27
SoftPLC
28
28
28
28
28
Timer
-
29
29
-
-
N>Nx and Nt>Nx
30
30
30
30
30
F>Fx
(1)
31
31
31
31
31
F>Fx
(2)
32
32
32
32
32
STO
33
33
33
33
33
No F160
34
34
34
34
34
No Alarm
35
35
35
35
35
No Fault and No Alarm
36
36
36
36
36
PLC11
37
37
37
-
-
No IOE Fault
38
38
38
-
-
No IOE Alarm
39
39
39
-
-
No Broken Cable Alarm
40
40
40
-
-
No IOE Alarm and No Broken Cable
Alarm
41
41
41
-
-
No IOE Fault and No Broken Cable
Alarm
42
42
42
-
-
Description:
They program the functions of the digital outputs, according to the options presented previously.
When the condition declared by the function is true, the digital output will be activated.
Example: Is>Ix function – when Is>Ix then DOx = saturated transistor and/or relay with the coil energized, and when
Is≤Ix then DOx = open transistor and/or relay with the coil not energized.
Some notes regarding the Digital Outputs are presented next.
-
Not Used:
it means that the digital outputs will remain always in a resting state, i.e., DOx = open transistor and/or
relay with the coil not energized.
-
Zero Speed:
it means that the motor speed is below the value adjusted in P0291 (Zero Speed Zone).
-
Torque > Tx and Torque < Tx:
they are valid only for P0202 = 3 or 4 (Vector Control). In those functions
"Torque" corresponds to the motor torque as indicated at parameter P0009.
-
Remote:
it means that the inverter is operating in Remote situation.
-
Run:
it corresponds to enabled inverter. In this moment the IGBTs are commutating, and the motor may be at any
speed, inclusive zero.
-
Ready:
it corresponds to the inverter without fault and without undervoltage.
-
No Fault:
it means that the inverter is not disabled by any type of fault.
Summary of Contents for CFW-11 Series
Page 2: ......
Page 54: ...2 4 2 General Information ...
Page 58: ...About the CFW 11 3 3 4 ...
Page 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Page 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Page 94: ...Available Control Types 8 2 8 ...
Page 118: ...VVW Control 10 8 10 ...
Page 182: ...Functions Common to All the Control Modes 12 26 12 ...
Page 220: ...Dynamic Braking 14 4 14 ...