Quick Parameter Reference, Faults and Alarms
0-1
0
Parameter
Function
Adjustable Range
Factory Setting
User
Setting
Properties
Groups
Pag.
P0000
Access to Parameters
0 to 9999
0
-
-
P0001
Speed Reference
0 to 18000 rpm
-
RO
09
P0002
Motor Speed
0 to 18000 rpm
-
RO
09
P0003
Motor Current
0.0 to 4500.0 A
-
RO
09
P0004
DC Link Voltage (U
d
)
0 to 2000 V
-
RO
09
P0005
Motor Frequency
0.0 to 1020.0 Hz
-
RO
09
P0006
VFD Status
0 = Ready
1 = Run
2 = Undervoltage
3 = Fault
4 = Self-Tuning
5 = Configuration
6 = DC-Braking
7 = STO
-
RO
09
P0007
Motor Voltage
0 to 2000 V
-
RO
09
P0009
Motor Torque
-1000.0 to 1000.0 %
-
RO
09
P0010
Output Power
0.0 to 6553.5 kW
-
RO
09
P0011
Output Cos phi
0.00 to 1.00
-
RO
09
P0012
DI8 to DI1 Status
Bit 0 = DI1
Bit 1 = DI2
Bit 2 = DI3
Bit 3 = DI4
Bit 4 = DI5
Bit 5 = DI6
Bit 6 = DI7
Bit 7 = DI8
-
RO
09, 40
P0013
DO5 to DO1 Status
Bit 0 = DO1
Bit 1 = DO2
Bit 2 = DO3
Bit 3 = DO4
Bit 4 = DO5
-
RO
09, 41
P0014
AO1 Value
0.00 to 100.00 %
-
RO
09, 39
P0015
AO2 Value
0.00 to 100.00 %
-
RO
09, 39
P0016
AO3 Value
-100.00 to 100.00 %
-
RO
09, 39
P0017
AO4 Value
-100.00 to 100.00 %
-
RO
09, 39
P0018
AI1 Value
-100.00 to 100.00 %
-
RO
09, 38, 95
P0019
AI2 Value
-100.00 to 100.00 %
-
RO
09, 38, 95
P0020
AI3 Value
-100.00 to 100.00 %
-
RO
09, 38, 95
P0021
AI4 Value
-100.00 to 100.00 %
-
RO
09, 38, 95
P0023
Software Version
0.00 to 655.35
-
RO
09, 42
P0025
DI16 to DI9 Status
Bit 0 = DI9
Bit 1 = DI10
Bit 2 = DI11
Bit 3 = DI12
Bit 4 = DI13
Bit 5 = DI14
Bit 6 = DI15
Bit 7 = DI16
RO
09, 40
P0026
DO13 to DO6 Status
Bit 0 = DO6
Bit 1 = DO7
Bit 2 = DO8
Bit 3 = DO9
Bit 4 = DO10
Bit 5 = DO11
Bit 6 = DO12
Bit 7 = DO13
RO
09, 41
P0027
Accessories Config. 1
0000h to FFFFh
-
RO
09, 42
P0028
Accessories Config. 2
0000h to FFFFh
-
RO
09, 42
P0029
Power Hardware Config
Bit 0 to 5 = Rated Current
Bit 6 and 7 = Rated Voltage
Bit 8 = EMC Filter
Bit 9 = Safety Relay
Bit 10 = (0)24V/(1)DC Link
Bit 11 = DC Special
Hardware
Bit 12 = Dyn.Brak. IGBT
Bit 13 = Special
Bit 14 and 15 = Reserved
-
RO
09, 42
QUICK PARAMETER REFERENCE, FAULTS AND ALARMS
Summary of Contents for CFW-11 Series
Page 2: ......
Page 54: ...2 4 2 General Information ...
Page 58: ...About the CFW 11 3 3 4 ...
Page 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Page 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Page 94: ...Available Control Types 8 2 8 ...
Page 118: ...VVW Control 10 8 10 ...
Page 182: ...Functions Common to All the Control Modes 12 26 12 ...
Page 220: ...Dynamic Braking 14 4 14 ...