0
Parameter
Function
Adjustable Range
Factory Setting
User
Setting
Properties
Groups
Pag.
P0813
Temper. V-B5/IGBT V5
-20.0 to 150.0 °C
-
CFW-11M
and RO
09, 45
P0814
Temper. W-B5/IGBT W5
-20.0 to 150.0 °C
-
CFW-11M
and RO
09, 45
P0815
Current U-B1/IGBT U1
-1000.0 to 2000.0 A
-
CFW-11M,
FRAME H
and RO
09, 45
P0816
Current V-B1/IGBT V1
-1000.0 to 2000.0 A
-
CFW-11M,
FRAME H
and RO
09, 45
P0817
Current W-B1/IGBT W1
-1000.0 to 2000.0 A
-
CFW-11M,
FRAME H
and RO
09, 45
P0818
Current U-B2/IGBT U2
-1000.0 to 2000.0 A
-
CFW-11M,
FRAME H
and RO
09, 45
P0819
Current V-B2/IGBT V2
-1000.0 a 2000.0 A
-
CFW-11M,
FRAME H
and RO
09, 45
P0820
Current W-B2/IGBT W2
-1000.0 to 2000.0 A
-
CFW-11M,
FRAME H
and RO
09, 45
P0821
Current U-B3/IGBT U3
-1000.0 to 2000.0 A
-
CFW-11M
and RO
09, 45
P0822
Current V-B3/IGBT V3
-1000.0 to 2000.0 A
-
CFW-11M
and RO
09, 45
P0823
Current W-B3/IGBT W3
-1000.0 to 2000.0 A
-
CFW-11M
and RO
09, 45
P0824
Current U-B4/IGBT U4
-1000.0 to 2000.0 A
-
CFW-11M
and RO
09, 45
P0825
Current V-B4/IGBT V4
-1000.0 to 2000.0 A
-
CFW-11M
and RO
09, 45
P0826
Current W-B4/IGBT W4
-1000.0 to 2000.0 A
-
CFW-11M
and RO
09, 45
P0827
Current U-B5/IGBT U5
-1000.0 to 2000.0 A
-
CFW-11M
and RO
09, 45
P0828
Current V-B5/IGBT V5
-1000.0 to 2000.0 A
-
CFW-11M
and RO
09, 45
P0829
Current W-B5/IGBT W5
-1000.0 to 2000.0 A
-
CFW-11M
and RO
09, 45
P0832
DIM1 Function
0 = Not Used
1 = No Ext.Fault IPS
2 = No Refrig. Fault
3 = No Br Overt Fault
4 = No Rect.Overt F
5 = No Rect.Temp Al
6 = No Rect. Fault
0
CFW-11M
45, 40
P0833
DIM2 Function
See options in P0832
0
CFW-11M
45, 40
P0834
DIM1 DIM2 Status
Bit 0 = DIM1
Bit 1 = DIM2
-
CFW-11M
and RO
09, 40
P0835
Ret. Temp. Phase R
-20.0 to 150.0 °C
-
FRAME H
and RO
09, 45
P0836
Ret. Temp. Phase S
-20.0 to 150.0 °C
-
FRAME H
and RO
09, 45
P0837
Ret. Temp. Phase T
-20.0 to 150.0 °C
-
FRAME H
and RO
09, 45
P0918
Profibus Address
1 to 126
1
115
P0922
Profibus Teleg. Sel.
1 = Std. Teleg. 1
2 = Telegram 100
3 = Telegram 101
4 = Telegram 102
5 = Telegram 103
6 = Telegram 104
7 = Telegram 105
8 = Telegram 106
9 = Telegram 107
1
CFG
115
P0944
Fault Message Counter
0 to 65535
RO
09, 115
Summary of Contents for CFW-11 Series
Page 2: ......
Page 54: ...2 4 2 General Information ...
Page 58: ...About the CFW 11 3 3 4 ...
Page 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Page 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Page 94: ...Available Control Types 8 2 8 ...
Page 118: ...VVW Control 10 8 10 ...
Page 182: ...Functions Common to All the Control Modes 12 26 12 ...
Page 220: ...Dynamic Braking 14 4 14 ...