Quick Parameter Reference, Faults and Alarms
0-15
0
Parameter
Function
Adjustable Range
Factory Setting
User
Setting
Properties
Groups
Pag.
P0278
DO4 Function
0 = Not Used
1 = N* > Nx
2 = N > Nx
3 = N < Ny
4 = N = N*
5 = Zero Speed
6 = Is > Ix
7 = Is < Ix
8 = Torque > Tx
9 = Torque < Tx
10 = Remote
11 = Run
12 = Ready
13 = No Fault
14 = No F070
15 = No F071
16 = No F006/21/22
17 = No F051/54/57
18 = No F072
19 = 4-20mA OK
20 = P0695 Value
21 = Forward
22 = Proc. V. > PVx
23 = Proc. V. < PVy
24 = Ride-Through
25 = Pre-Charge OK
26 = Fault
27 = Time Enab > Hx
28 = SoftPLC
29 = Not Used
30 = N>Nx/Nt>Nx
31 = F > Fx (1)
32 = F > Fx (2)
33 = STO
34 = No F160
35 = No Alarm
36 = No Fault/Alarm
37 to 42 = Not Used
0
CFG
41
P0279
DO5 Function
See options in P0278
0
CFG
41
P0281
Fx Frequency
0.0 to 300.0 Hz
4.0 Hz
-
41
P0282
Fx Hysteresis
0.0 to 15.0 Hz
2.0 Hz
-
41
P0283
DO2 ON Time
0.0 to 300.0 s
0.0 s
-
41
P0284
DO2 OFF Time
0.0 to 300.0 s
0.0 s
-
41
P0285
DO3 ON Time
0.0 to 300.0 s
0.0 s
-
41
P0286
DO3 OFF Time
0.0 to 300.0 s
0.0 s
-
41
P0287
Nx/Ny Hysteresis
0 to 900 rpm
18 (15) rpm
-
41
P0288
Nx Speed
0 to 18000 rpm
120 (100) rpm
-
41
P0289
Ny Speed
0 to 18000 rpm
1800 (1500) rpm
-
41
P0290
Ix Current
0 to 2 x I
nom-ND
1.0 x I
nom-ND
-
41
P0291
Zero Speed Zone
0 to 18000 rpm
18 (15) rpm
-
35, 41, 46
P0292
N = N* Band
0 to 18000 rpm
18 (15) rpm
-
41
P0293
Tx Torque
0 to 200 %
100 %
-
41
P0294
Hx Time
0 to 6553 h
4320 h
-
41
Summary of Contents for CFW-11 Series
Page 2: ......
Page 54: ...2 4 2 General Information ...
Page 58: ...About the CFW 11 3 3 4 ...
Page 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Page 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Page 94: ...Available Control Types 8 2 8 ...
Page 118: ...VVW Control 10 8 10 ...
Page 182: ...Functions Common to All the Control Modes 12 26 12 ...
Page 220: ...Dynamic Braking 14 4 14 ...