Digital and Analog Inputs and Outputs
13-34
13
LOCAL
REFERENCE (P0221)
LOCAL
REFERENCE
REMOTE
REFERENCE
LOCAL
COMMANDS
REMOTE
COMMANDS
(P0220)
LOCAL/REMOTE Selection
REFERENCE
COMMANDS
COMMANDS
REFERENCE
FORWARD/REVERSE
(P0223)
JOG (P0225)
RUN/STOP (P0224)
REMOTE
REFERENCE (P0222)
FORWARD/REVERSE
(P0226)
JOG (P0228)
RUN/STOP (P0227)
Figure 13.9 -
Local/Remote situation block diagram
13.3 3-WIRE COMMAND [33]
The group defined as "3-Wire Command" refers to the function Run/Stop programmed via digital inputs.
With this function it is possible to activate or deactivate the motor by means of pulses at the digital inputs
configured as Run (DIx = 6) and Stop (DIx = 7). It is important to notice that the Stop pulse is inverted, i.e., a
transition from +24 V to 0 V.
For a better understanding of this function it is recommended to verify the
(k)
.
13.4 FORWARD RUN/REVERSE RUN COMMANDS [34]
The FWD Run/REV Run function can be used to command the motor in the forward direction and in the reverse
direction by means of digital inputs.
With the application of +24 V to the input programmed for FWD Run (DIx = 4), the motor accelerates in the
forward direction until reaching the speed reference. Once the FWD Run input has been released (0 V) and +24
V has been applied at the input programmed for REV Run (DIx = 5), the CFW-11 will activate the motor in the
reverse direction until it reaches the speed reference. Refer to the
(l)
.
Summary of Contents for CFW-11 Series
Page 2: ......
Page 54: ...2 4 2 General Information ...
Page 58: ...About the CFW 11 3 3 4 ...
Page 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Page 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Page 94: ...Available Control Types 8 2 8 ...
Page 118: ...VVW Control 10 8 10 ...
Page 182: ...Functions Common to All the Control Modes 12 26 12 ...
Page 220: ...Dynamic Braking 14 4 14 ...