P0321 – DC Link Power Loss
Adjustable
Range:
178 to 282 V
308 to 616 V
308 to 616 V
308 to 616 V
308 to 616 V
425 to 737 V
425 to 737 V
486 to 885 V
486 to 885 V
Factory
Setting:
252 V (P0296 = 0)
436 V (P0296 = 1)
459 V (P0296 = 2)
505 V (P0296 = 3)
551 V (P0296 = 4)
602 V (P0296 = 5)
660 V (P0296 = 6)
689 V (P0296 = 7)
792 V (P0296 = 8)
P0322 – DC Link Ride-Through
Adjustable
Range:
178 to 282 V
308 to 616 V
308 to 616 V
308 to 616 V
308 to 616 V
425 to 737 V
425 to 737 V
486 to 885 V
486 to 885 V
Factory
Setting:
245 V (P0296 = 0)
423 V (P0296 = 1)
446 V (P0296 = 2)
490 V (P0296 = 3)
535 V (P0296 = 4)
585 V (P0296 = 5)
640 V (P0296 = 6)
668 V (P0296 = 7)
768 V (P0296 = 8)
P0323 – DC Link Power Back
Adjustable
Range:
178 to 282 V
308 to 616 V
308 to 616 V
308 to 616 V
308 to 616 V
425 to 737 V
425 to 737 V
486 to 885 V
486 to 885 V
Factory
Setting:
267 V (P0296 = 0)
462 V (P0296 = 1)
486 V (P0296 = 2)
535 V (P0296 = 3)
583 V (P0296 = 4)
638 V (P0296 = 5)
699 V (P0296 = 6)
729 V (P0296 = 7)
838 V (P0296 = 8)
Properties:
Vector
Access groups
via HMI:
01 PARAMETER GROUPS
44 FlyStart/RideThru
Description:
- P0321 – defines the U
d
voltage level under which the line loss will be detected.
- P0322 – defines the U
d
voltage level that the inverter will try to keep regulated, so that the motor keeps operating.
- P0323 – defines the U
d
voltage level at which the inverter will identify the return of the line, and from where the
motor must be reaccelerated.
NOTE!
These parameters work together with the parameters P0325 and P0326 for the Ride-Through in
vector control.
P0325 – Ride-Through Proportional Gain
Adjustable
Range:
0.0 to 63.9
Factory
Setting:
22.8
Summary of Contents for CFW-11 Series
Page 2: ......
Page 54: ...2 4 2 General Information ...
Page 58: ...About the CFW 11 3 3 4 ...
Page 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Page 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Page 94: ...Available Control Types 8 2 8 ...
Page 118: ...VVW Control 10 8 10 ...
Page 182: ...Functions Common to All the Control Modes 12 26 12 ...
Page 220: ...Dynamic Braking 14 4 14 ...