Chapter 9
Using LTE-TDD Signal Analyzer
JD700B Series User’s Guide
339
10
Toggle the
Plot
soft key and select
Stop
to stop plotting.
11
Press the
SAVE/LOAD
hot key to save the result.
See “Using save” on page 35 for more information.
NOTE
The instrument does not automatically save the collected data. It is recommended that
you save the result. Otherwise, you will lose all the collected data.
Setting limit for route map
You can set the thresholds for each test item.
Procedure
1
Press the
LIMIT
hot key.
2
Select the plot items and set the limits as needed:
To set the limit for
Select
Set
RSRP
RSRP
Excellent, Very Good, Good, Fair, Poor (dBm)
RSRQ
RSRQ
Good, Fair, Poor (dB)
RS-SINR
RS-SINR
Good, Fair, Poor (dB)
S-SS RSSI
S-SS RSSI
Excellent, Very Good, Good, Fair, Poor (dBm)
P-SS Power
P-SS Power
Excellent, Very Good, Good, Fair, Poor (dBm)
S-SS Power
S-SS Power
Excellent, Very Good, Good, Fair, Poor (dBm)
S-SS Ec/Io
S-SS Ec/Io
Good, Fair, Poor (dB)
3
Optional
. Go to
SAVE/LOAD > Save
, and then select
Limit
to save the limit settings.
See “Using save” on page 35 for more information.
Measurement example
Figure 195 Route map measurement (RSRP) with LTE-TDD OTA signal analyzer